E

Note : 

Make sure all seals and accessories   

are correctly fitted.

• To eliminate air or insect intrusion, 

use the balance of the seal provided 
with your air conditioner to fill in any 
left opening not properly covered.

C

ASEMENT

W

INDOW

I

NSTALLATION

• This air conditioner is designed to fit into most casement type windows with a minimum   

opening of 15 1/2” wide x 22” high.

• For safety reasons, ideally the unit should be installed in a closed or fixed window.
• However, if the unit has to be installed in an open window frame, the window should be 

secured from the outside or completely removed.

1.Closed or fixed window :  

• Ideally, install the air conditioner in a close or fixed window sash.   
• If the unit is to be installed in or next to a movable sash, remove catch and handle.
• Secure the window in closed position.
• Remove the glass panes and parting strips to the height necessary to install the 

unit.

• Install the air conditioner as per the instructions described for the sliding windows. 

2. Open window frame :

• Remove handle mechanism and catch. Open the window sash back against the 

building exterior wall.

• Secure the window or remove completely where possible. 

Install the air conditioner as per the instructions described for the sliding windows. 

Note : 

A filler panel will be required if the window opening is larger than 15 1/2”. 

• The panel should made of wood -  3/4” thickness, and should run full length of window.
• Securely anchor the panel to one side of the window.

Important : 

For wood frame casement windows, it could be necessary to build a wood frame - 

1” minimum thickness, with a 15 1/2” opening. 

• Securely fix and seal the wood frame into the window opening. 
• Follow usual instructions for installing the air conditioner.

E

Drilled holes

Speed clips

Foam seal

Mounting rail

3/8” screws

Summary of Contents for 13-04596

Page 1: ...MODELS 13 04596 13 04597 00220 17 12 06 Please read the following owner s manual before using this air conditioner Keep this manual along with your proof of purchase in a safe place for future refere...

Page 2: ...ent window installation 8 UNIT OPERATION Electronic control models LED display control panel 9 Cooling 10 Fan only 10 Energy Saving 11 Setting the timer 11 Air Exchanger 11 Remote Control 12 Mechanica...

Page 3: ...t the power cord 8 Always check the power cord for signs of damage before use If the power cord is damaged contact SUNRISE TRADEX Customer Service see end of this manual 9 Do not install or use the un...

Page 4: ...ade and Phillips screwdrivers D Utility knife or scissors E Drill with 1 8 bit F Safety glasses G Measuring tape Spare screws not shown A B C D E F G 3 8 screw 4 1 self tapping screw 4 Support platfor...

Page 5: ...ord 125 V 103 5 min 126 5 max 0 15 A 15A time delay fuse or circuit breaker Do not connect to an outlet use by other appliances preferably use on a single outlet circuit The air conditioner must be gr...

Page 6: ...e width of the support platform and should be flush with the back edge of the sill The thickness should be gauged on the gap to fill in beetween the support platform and the window track Fig B 6 Pull...

Page 7: ...sert the sliders upward making sure the filler panel aligns in sliders 16 With sliders up against top retainer drill on each side a 1 8 hole through the window frame in alignment with the pre drilled...

Page 8: ...window in closed position Remove the glass panes and parting strips to the height necessary to install the unit Install the air conditioner as per the instructions described for the sliding windows 2...

Page 9: ...alternate between o C and o F Decrease increase the hours when setting the timer for an automatic start or shut off of the air conditioner To set fan speeds AUTO LOW MEDIUM or HIGH each level is paire...

Page 10: ...provide an optimum comfort level based on the set temperature The fan speed will increase or decrease in order to adjust the cooling airflow as per the set temperature This level can be activated onl...

Page 11: ...or shut off of the air conditioner Automatic start 1 Press on TIMER when the unit is OFF the TIMER icon will light on 2 Press or to set the numbers of hours 1 24 before the automatic start 3 The LED...

Page 12: ...e the turn on Presss TIMER again to cancel the timer Automatic shut off Press on TIMER when the unit is ON Then press the keys to set the numbers of hours 1 24 before the shut off Press TIMER again to...

Page 13: ...the compressor is off cycle is completed Turn the THERMOSTAT TEMPERATURE rotary control to a mid setting 5 Then when necessary set the emperature to the desired level of room comfort by turning the TH...

Page 14: ...shwasher nor use chemical products or abrasive detergents CLEANING THE HOUSING 1 Turn the unit off and unplug the unit 2 Wipe the surface of the unit with a soft damp cloth Never immerse the unit 3 Ai...

Page 15: ...ns blinds etc Close or move the heat source Clean the air filter Change set temperature Increase the fan speed or change the unit mode 15 Set the air exchanger to CLOSED Check the room cooling chart a...

Page 16: ...CE Contact SUNRISE TRADEX Customer Service for Replacement parts Technical support Warranty claims Customer service AIR CONDITIONER SELECTION GUIDE 9 14 m 100 150 ft 5 000 14 23 m 150 250 ft 6 000 23...

Page 17: ...mage to the finish of the unit enclosure or to other outer features caused by wear 4 Filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by...

Reviews: