UNPACKING THE AIR CONDITIONER

Remove and save the shipping carton and packing materials for future storage or transport 
of the unit.  Otherwise, dispose of packaging materials, waste recycling where possible. 
Remove tape and glue residue from surface before turning on the air conditioner. Rub a 
small amount of liquid dish soap over the glue residue with your fingers. Wipe with warm 
water and dry.

• Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to 

remove tape or glue. These products can damage the surface of your air conditioner. 

• Handle with care. We recommend that 2 persons move and install this air conditioner.

ELECTRICAL REQUIREMENTS

The electrical ratings are listed on the rating plate of this air conditioner. 

• Make sure to follow the requirements for the type of plug ending the power supply cord :

- 125 V (103,5 min. - 126,5 max.)
- 0-15 A
- 15A time-delay fuse or circuit breaker
-

Do not connect to an outlet use by other appliances ; 

preferably, use on a single outlet circuit

• The air conditioner must be grounded ; it is equipped with a power supply cord ending 

with a grounded plug (3 prongs) and must be plugged into a properly rated 3-prong 
grounded outlet.

• If you do not have a grounded outlet available,  contact a qualified electrician to have a 

grounded outlet properly installed.

• Do not alter the power supply plug by removing the ground plug.

RECOMMENDATIONS

This air conditioner is designed for an easy installation in a vertical window (casement or 

sliding type). It is not designed for single or double-hung window.

Make sure you install the air conditioner in a window that will hold the weight (refer to the 

rating plate on your unit) ; reinforce if necessary.

• Secure the unit as per the instructions.

INSTALLATION

Horizontal air vent

Interior air outlet

Air filter
(under the louvers)

Interior air inlet grille

Front panel

Air exchanger

Control panel

Enclosure

Vertical air vent

Exterior air inlet

Summary of Contents for 13-04596

Page 1: ...MODELS 13 04596 13 04597 00220 17 12 06 Please read the following owner s manual before using this air conditioner Keep this manual along with your proof of purchase in a safe place for future refere...

Page 2: ...ent window installation 8 UNIT OPERATION Electronic control models LED display control panel 9 Cooling 10 Fan only 10 Energy Saving 11 Setting the timer 11 Air Exchanger 11 Remote Control 12 Mechanica...

Page 3: ...t the power cord 8 Always check the power cord for signs of damage before use If the power cord is damaged contact SUNRISE TRADEX Customer Service see end of this manual 9 Do not install or use the un...

Page 4: ...ade and Phillips screwdrivers D Utility knife or scissors E Drill with 1 8 bit F Safety glasses G Measuring tape Spare screws not shown A B C D E F G 3 8 screw 4 1 self tapping screw 4 Support platfor...

Page 5: ...ord 125 V 103 5 min 126 5 max 0 15 A 15A time delay fuse or circuit breaker Do not connect to an outlet use by other appliances preferably use on a single outlet circuit The air conditioner must be gr...

Page 6: ...e width of the support platform and should be flush with the back edge of the sill The thickness should be gauged on the gap to fill in beetween the support platform and the window track Fig B 6 Pull...

Page 7: ...sert the sliders upward making sure the filler panel aligns in sliders 16 With sliders up against top retainer drill on each side a 1 8 hole through the window frame in alignment with the pre drilled...

Page 8: ...window in closed position Remove the glass panes and parting strips to the height necessary to install the unit Install the air conditioner as per the instructions described for the sliding windows 2...

Page 9: ...alternate between o C and o F Decrease increase the hours when setting the timer for an automatic start or shut off of the air conditioner To set fan speeds AUTO LOW MEDIUM or HIGH each level is paire...

Page 10: ...provide an optimum comfort level based on the set temperature The fan speed will increase or decrease in order to adjust the cooling airflow as per the set temperature This level can be activated onl...

Page 11: ...or shut off of the air conditioner Automatic start 1 Press on TIMER when the unit is OFF the TIMER icon will light on 2 Press or to set the numbers of hours 1 24 before the automatic start 3 The LED...

Page 12: ...e the turn on Presss TIMER again to cancel the timer Automatic shut off Press on TIMER when the unit is ON Then press the keys to set the numbers of hours 1 24 before the shut off Press TIMER again to...

Page 13: ...the compressor is off cycle is completed Turn the THERMOSTAT TEMPERATURE rotary control to a mid setting 5 Then when necessary set the emperature to the desired level of room comfort by turning the TH...

Page 14: ...shwasher nor use chemical products or abrasive detergents CLEANING THE HOUSING 1 Turn the unit off and unplug the unit 2 Wipe the surface of the unit with a soft damp cloth Never immerse the unit 3 Ai...

Page 15: ...ns blinds etc Close or move the heat source Clean the air filter Change set temperature Increase the fan speed or change the unit mode 15 Set the air exchanger to CLOSED Check the room cooling chart a...

Page 16: ...CE Contact SUNRISE TRADEX Customer Service for Replacement parts Technical support Warranty claims Customer service AIR CONDITIONER SELECTION GUIDE 9 14 m 100 150 ft 5 000 14 23 m 150 250 ft 6 000 23...

Page 17: ...mage to the finish of the unit enclosure or to other outer features caused by wear 4 Filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by...

Reviews: