ForestAir 13-04596 Owner'S Manual Download Page 7

INSTALLATION

7

8. • Cut two pieces of adhesive foam 

seal to the height of the window 
opening.

• Remove the backing and apply on

the inside edges of the vertical 
window sash frame (fig. C).

9. • Put the unit on the support platform. 

• Check for the unit side rail to butt  

against the edge of the window 
vertical frame.

If the unit side rail does not 
correctly fit, remove the unit and 
adjust leveling bolt.

12. Secure the installation by fixing the speed clips on the inside edge of the window top and 

bottom frame (fig. E, 

next page

).

13. Cut a seal to proper length and 

insert it between the inside and the    
outside window sash 
(fig. E, 

next page

)

14. •Place the top retainer on the top 

edge of the filler panel. 

• Then place the bottom edge of the     

filler panel Into the groove of the 
unit bottom mounting rail. 

• The filler panel should be trimmed 

to tightly fit in the window opening  
(fig. C).

15. Insert the sliders upward making 

sure the filler panel aligns in sliders.

16. •With sliders up against top retainer, drill on each side a 1/8” hole through the 

window frame in alignment with the pre-drilled holes in the sliders.      

•Insert 3/8” screws and tighten.

10.• Drill 2 x 1/8” holes through the window sash frame in alignment with the holes in 

the unit bottom rail (factory installed). 

• Insert 2 x 3/8” screws through these holes. 
• If the window sash frame is not long enough to use the pre-drilled holes, drill new 

holes off and attach the bottom part of the air conditioner to the support platform. 

• The air conditioner should be firmly anchored to window rail frame or support 

platform (Fig. D).

11. • Close the window. 

• Check for the inside edge of window vertical frame to close tightly on side of unit. 
• Cut remaining adhesive foam seal to width of the window opening. 
• Remove backing and fix it into inside edge of the top window frame (Fig.C).

C

C

Foam seal

Foam seal

Top retainer

Filler panel

Slider

Support platform

Bottom mounting rail

3/8” screws

Drilled holes

Window sash frame

C

D

Summary of Contents for 13-04596

Page 1: ...MODELS 13 04596 13 04597 00220 17 12 06 Please read the following owner s manual before using this air conditioner Keep this manual along with your proof of purchase in a safe place for future refere...

Page 2: ...ent window installation 8 UNIT OPERATION Electronic control models LED display control panel 9 Cooling 10 Fan only 10 Energy Saving 11 Setting the timer 11 Air Exchanger 11 Remote Control 12 Mechanica...

Page 3: ...t the power cord 8 Always check the power cord for signs of damage before use If the power cord is damaged contact SUNRISE TRADEX Customer Service see end of this manual 9 Do not install or use the un...

Page 4: ...ade and Phillips screwdrivers D Utility knife or scissors E Drill with 1 8 bit F Safety glasses G Measuring tape Spare screws not shown A B C D E F G 3 8 screw 4 1 self tapping screw 4 Support platfor...

Page 5: ...ord 125 V 103 5 min 126 5 max 0 15 A 15A time delay fuse or circuit breaker Do not connect to an outlet use by other appliances preferably use on a single outlet circuit The air conditioner must be gr...

Page 6: ...e width of the support platform and should be flush with the back edge of the sill The thickness should be gauged on the gap to fill in beetween the support platform and the window track Fig B 6 Pull...

Page 7: ...sert the sliders upward making sure the filler panel aligns in sliders 16 With sliders up against top retainer drill on each side a 1 8 hole through the window frame in alignment with the pre drilled...

Page 8: ...window in closed position Remove the glass panes and parting strips to the height necessary to install the unit Install the air conditioner as per the instructions described for the sliding windows 2...

Page 9: ...alternate between o C and o F Decrease increase the hours when setting the timer for an automatic start or shut off of the air conditioner To set fan speeds AUTO LOW MEDIUM or HIGH each level is paire...

Page 10: ...provide an optimum comfort level based on the set temperature The fan speed will increase or decrease in order to adjust the cooling airflow as per the set temperature This level can be activated onl...

Page 11: ...or shut off of the air conditioner Automatic start 1 Press on TIMER when the unit is OFF the TIMER icon will light on 2 Press or to set the numbers of hours 1 24 before the automatic start 3 The LED...

Page 12: ...e the turn on Presss TIMER again to cancel the timer Automatic shut off Press on TIMER when the unit is ON Then press the keys to set the numbers of hours 1 24 before the shut off Press TIMER again to...

Page 13: ...the compressor is off cycle is completed Turn the THERMOSTAT TEMPERATURE rotary control to a mid setting 5 Then when necessary set the emperature to the desired level of room comfort by turning the TH...

Page 14: ...shwasher nor use chemical products or abrasive detergents CLEANING THE HOUSING 1 Turn the unit off and unplug the unit 2 Wipe the surface of the unit with a soft damp cloth Never immerse the unit 3 Ai...

Page 15: ...ns blinds etc Close or move the heat source Clean the air filter Change set temperature Increase the fan speed or change the unit mode 15 Set the air exchanger to CLOSED Check the room cooling chart a...

Page 16: ...CE Contact SUNRISE TRADEX Customer Service for Replacement parts Technical support Warranty claims Customer service AIR CONDITIONER SELECTION GUIDE 9 14 m 100 150 ft 5 000 14 23 m 150 250 ft 6 000 23...

Page 17: ...mage to the finish of the unit enclosure or to other outer features caused by wear 4 Filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by...