21
Connection Example2
Master
Slave
Slave
<Menu Setting>
GRP? >> 700M
MU? >> Arbitrary
AID
>> 240
<Menu Setting>
GRP? >> 700S
MU? >> 240
AID
>> 241
<Menu Setting>
GRP? >> 700
S
MU? >> 240
AID
>> 242
3-3-2. Arcnet ID and Menu Settings
Arcnet ID
Note that when more than one unit is configured, different ID numbers (1-255) must be
assigned
to each unit configured within the ARCNET for control communication to be
possible. If ID numbers are overlapped in the Arcnet, communication cannot be properly
established. (See section 5. "Menu Operation" following for details.)
The Arcnet ID number can be changed in the AID item in the Setup menu. See section 5-1
“Making Settings" and section 5-2 "Setup Menu."
Menu Settings
The GRP and MU settings in the menu are different between master and slave units. Refer to
the table below for proper settings for your Auxiliary Units. See section 5-1
“Making Settings"
and section 5-2 "Setup Menu" for other menu settings.
Menu Item
Setting
Master
Slave
GRP?
700M
700S
MU?
Any value from 1 to 255
(This value is neglected.)
Arcnet ID of Master
NOTE
The Arcnet ID for HVS-AUX is set to 240 at factory default. The different ID numbers
must be set for each units.
VPS-700
TO OU
RS-422 1
VPS-700 OU
TO MU
75
Ω
termination
OFF
CONTROL A
HVS-AUX
(ID 240)
CONTROL A
HVS-AUX
(ID 241)
CONTROL A
HVS-AUX
(ID 242)
75
Ω
termination
ON
75
Ω
termination
ON
PC
-3
1
68
-1
CO
N
T
R
O
L
B
USO
RESTRITO