M-62 MICROPHONE CONNECTION
This system allows you to connect a maximum of 6
M-62
microphones in total, with a maximum of 3
microphones on each line.
Each microphone must be assigned an ID when it is connected for the first time. Please note that this ID
cannot be repeated within the same system.
To assign an ID to
M-62
, microphone, with the microphone turned off, press and hold one of the ZONE
buttons on the microphone itself while turning the microphone on (switch located on the back of the
M-62
).
You can be certain that the ID configuration is correct when the LED zone being pressed flashes several
times and finally remains lit, at which point you can stop pressing the ZONE button. Each ZONE button
identifies a different ID: ID: ZONE 1 equals ID 1, ZONE 2 equals ID 2, etc. The microphone identified by ID 1
will have priority to send messages over any other mics.
Connect the LINK output of the
M-62
microphone to the REMOTE MIC input of amplifier
MPZ-6241
using
the supplied data cable. Interconnect
M-62
microphones using the LINK connectors.
MPZ-6241
M-62
M-62
M-62
M-62
M-62
M-62
6 x M-62 MAX.
3 x M-62
MAX.
3 x M-62
MAX.
MPZ-6241
MULTIZONE AMPLIFIER
~ 115 V AC. 50/60 Hz FUSE: T5AL 250 V
~ 230 V AC. 50/60 Hz FUSE: T5AL 250 V
CLASS II WIRING
ONE ZONE: 50 W MAX.
TOTAL ALL ZONES: 240 W MAX.
CLASS II WIRING
CHIME
COM
CHIME
SIREN
GAIN
INPUT 4
REMOTE MIC
INPUT 3
MUTE
EMC
TEL
REC
OUT
INPUT
VOL
INPUT 2
INPUT 1
GAIN
SIREN
POWER CONSUMPTION: 320 W
PUSH
PUSH
PUSH
PUSH
MIC
LINE
P48 V
MIC
LINE
P48 V
MIC
P48 V
MIC
LINE
P48 V
LINE
PAGING WITH THE M-62 MICROPHONE
Press the TALK button on
M-62
, microphone to begin an announcement, press the TALK button again to
end the announcement.
If there is no other microphone emitting a message, the TALK and microphone LEDs will be green. If, on
the other hand, the TALK indicator light turns red, this indicates that there is another microphone sending a
message at that moment. The system will create a waiting queue for all microphones requesting to send a
message (the TALK indicator will appear as a red light) and will activate them in the same order in which the
requests were made.
If the message is interrupted by the microphone with ID 1 (priority), the system will wait to re-activate the
microphone that was interrupted until the ID1 (priority) microphone has completed its announcement.