background image

17.-

PWR:

system lED on/off indicator.

18.-

AC: 

lED indicator which lights up when the system is connected to 230 V AC.

BACK PANEL

1.-

AC socket: 

for connecting the AC power supply cable.

2.-

ON/OFF + 48 V PHANTOM: 

switches which allow you to activate or deactivate the 48 V DC Phantom

for each one of the microphone inputs 1 to 4.

3.-

ZONE 1 to 5: 

speaker outputs for each zone. for the connection of speakers in a 100 V high impedance

line.

4.-

OUTPUT:

general speaker output. for the connection of speakers in 4 or 8 Ω low impedance and in 100

or 70 V high impedance lines, connect the speaker line between the COm terminal  and the impedance
or line, in the desired V.

5.-

CHIME ACTIVE

: chime activation on contact closure. Chime should be selected in the CHimE, SiREN

selector button and the CHimE ACTiVE button should also be deactivated.

6.-

PRIORITY:

button which allows you to activate or deactivate priority through the microphone 1 level over

the rest of the inputs.

7.-

REMOTE:

input for connecting the zone selector microphone model 

M-512

, female D15 connector.

8.-

BATT  DC24V-: 

24 V DC power supply terminals. for the amplifier to work with 24 V DC

power supply, batteries, emergency power supply systems, etc. make the connection with 2.5 mm²
section cable to the – negative and + positive terminals.

Note

: when using the amplifier with 24 V DC, the power is reduced by approximately 20%.

9.-

GAIN

: control wheels which regulate the miC 1 to 4 input signal levels.

10.-

MIC 1 to 4: 

microphone inputs which use a combo connector (XlR and 6.3 mm jack), accepting signals

from  balanced  microphones,  unbalanced  from  30  –  600  Ω  and  balanced  electret  condenser
microphones that need 48 V phantom, present in pins 2 and 3 in the XlR connector.

11.-

INPUT LINE 1 and 2

: line inputs. for connecting audio sources, 2 x RCA connectors.

12.-

OUT LINE

: line output. Output signal for recording, mixer, power amp, etc., 2 x RCA connectors.

13.-

EMC

: emergency input prepared for connecting to the emergency output, RCA connector. When a

signal is detected in this input, it is sent to all the output zones at maximum volume and with priority over
the rest of the inputs. 

14.-

TEL. INPUT: 

telephone input terminal, RCA connector. for connecting to the telephone switchboard

output,  for  paging  from  the  switchboard  and  having  priority  over  the  rest  of  inputs.  Consult  the

EN

- 5 -

Summary of Contents for MPZ-5125

Page 1: ...MPZ 5125 P A AmPlifiER WiTH 5 OUTPUT ZONES EN Instruction Manual...

Page 2: ...llow ventilation Avoid direct sunlight heat sources and excessive dust Do not place the machine near magnetic elds or static electricity Do not use surfaces which vibrate or receive impact Do not pile...

Page 3: ...ealer when purchasing a similar product at no additional cost it also shows that the machine was put on the market after 13th August 2005 European Community Directive 2002 96 CE of Electrical and Elec...

Page 4: ...ALL lED indicator which lights up when all zones are active 6 ZONE 1 to 5 lED indicators for each zone They light up when the corresponding zone is active 7 ZONE 1 to 5 zone selection buttons for acti...

Page 5: ...SUPPLY DC24V 24 V DC power supply terminals for the ampli er to work with 24 V DC power supply batteries emergency power supply systems etc make the connection with 2 5 mm section cable to the negati...

Page 6: ...vate 2 or 4 chime tones on the back panel of the microphone Then select the zone or zones where you want the announcement to be sent using CH 1 to 5 buttons and press the CHimE button to send it The T...

Page 7: ...ted when a signal is detected in the input connector and therefore automatically weakening the miC1 to 4 and liNE 1 and 2 inputs so that the message can be heard clearly The next priority level is for...

Page 8: ...peakers must be connected in a series parallel circuit so that the speaker load impedance is equal to the ampli er output impedance and the power supplied by the ampli er does not exceed what is withs...

Page 9: ...9 EN BLOCK DIAGRAM...

Page 10: ...out 2 x RCA 600 1 V CONTROLS Tone Bass 10 dB Treble 10dB Volume mics 1 to 4 aux 1 2 chimes siren and general volume PHANTOM 48 V in mics 1 to 4 selectable PRIORITY Emergency through signal level Tel...

Page 11: ...ges burns spilt liquids or other substances excessive humidity battery deterioration and internal manipulation of the device the software or its components by unauthorized persons and in general any u...