background image

- 6 -

EN

switchboard characteristics in order to adjust it to the amplifier input level. 

15.-

TEL. VOLUME: 

volume control for the TEl. iNPUT. it allows you to adjust the volume of the telephone

switchboard which is connected to the TEl. iNPUT terminal.

16.-

CHIME

: for selecting between the 2 and 4 tone chimes.

INSTRUCTIONS FOR USE 

ZONE SELECTION WITH BACKGROUND MUSIC

Select the zones where you want the background music to be played, by pressing the corresponding ZONE
1 to 5 buttons on the front panel of the system.

The  background  music  will  be  cut  off  when  there  is  an  announcement  in  one  of  the  zones.  Once  the
announcement has finished, the background music will return to the selected zones.

CONNECTING THE M-512 MICROPHONE

To connect the m-512 model microphone to the system, use the cable supplied with the microphone.

The microphone is powered through the audio and data cable. in the case of the distance being more than
10 m there could be loss through the audio and data cable. Therefore, the microphone should be powered
with a local 24 V DC power supply with the supplied cable. 

PAGING WITH THE M-512 MICROPHONE

Select  the  zones  where  you  want  the  announcements  to  be  sent,  using  the  CH  1  to  5  buttons  on  the
microphone and then press the TAlK button. When the announcement has finished, press the TAlK button
again and disable the zone selection in the 

M-512

model microphone.

Note

: The zone selection is disabled in the amplifier while there is a zone selected in the 

M-512

model

microphone.

CHIMES

The chimes can be used in 3 ways: 

The chimes can be reproduced at a distance through the microphone mod. m-512. firstly, select if you want
to activate 2 or 4 chime tones on the back panel of the microphone. Then, select the zone or zones where
you want the announcement to be sent using CH 1 to 5 buttons and press the CHimE button to send it. The
TAlK button must be pressed down for the chimes to be played.

To play the chimes from a distance, firstly, you must activate the chimes on the front panel using the SiREN
CHimE button. Then you have to select the o or 4 chime tones on the back panel of the amplifier. Afterwards,
in order to play the chimes you have to close the CHimE ACTiVE contacts on the back panel using the push
button (or the microphone push button). 

in order to play the chimes from the amplifier, they must be activated on the front panel using the SiREN
CHimE button. Select if you want 2 or 4 chime tones on the back panel of the amplifier. Then, play the chimes
with the CHimE ACTiVE button on the front panel.

SIREN 

To play the siren from the amplifier, it must be activated on the front panel with the SiREN button. Use the
VOlUmE control button to adjust the volume in the siren output.

When you activate the siren, you will only be able to hear it in the selected zones.

Note: So that the siren has priority depending on the level, the VOlUmE control must be at least at mid
volume.

EMC EMERGENCY INPUT

When a signal is detected in the EmC input, this is sent to all output zones at maximum volume.

INPUT PRIORITY

The priority function automatically weakens the input levels with lower priority so that the message sent out
by those with higher priority can be heard clearly.

The EmC input has maximum priority over the rest of the inputs. The EmC input priority is activated when a
signal is detected in the input connector, automatically weakening the TEl. iNPUT, the microphone model

M-512

signal, miC 1 to 4 and liNE 1 and 2 inputs so that the message can be heard clearly.

Summary of Contents for MPZ-5125

Page 1: ...MPZ 5125 P A AmPlifiER WiTH 5 OUTPUT ZONES EN Instruction Manual...

Page 2: ...llow ventilation Avoid direct sunlight heat sources and excessive dust Do not place the machine near magnetic elds or static electricity Do not use surfaces which vibrate or receive impact Do not pile...

Page 3: ...ealer when purchasing a similar product at no additional cost it also shows that the machine was put on the market after 13th August 2005 European Community Directive 2002 96 CE of Electrical and Elec...

Page 4: ...ALL lED indicator which lights up when all zones are active 6 ZONE 1 to 5 lED indicators for each zone They light up when the corresponding zone is active 7 ZONE 1 to 5 zone selection buttons for acti...

Page 5: ...SUPPLY DC24V 24 V DC power supply terminals for the ampli er to work with 24 V DC power supply batteries emergency power supply systems etc make the connection with 2 5 mm section cable to the negati...

Page 6: ...vate 2 or 4 chime tones on the back panel of the microphone Then select the zone or zones where you want the announcement to be sent using CH 1 to 5 buttons and press the CHimE button to send it The T...

Page 7: ...ted when a signal is detected in the input connector and therefore automatically weakening the miC1 to 4 and liNE 1 and 2 inputs so that the message can be heard clearly The next priority level is for...

Page 8: ...peakers must be connected in a series parallel circuit so that the speaker load impedance is equal to the ampli er output impedance and the power supplied by the ampli er does not exceed what is withs...

Page 9: ...9 EN BLOCK DIAGRAM...

Page 10: ...out 2 x RCA 600 1 V CONTROLS Tone Bass 10 dB Treble 10dB Volume mics 1 to 4 aux 1 2 chimes siren and general volume PHANTOM 48 V in mics 1 to 4 selectable PRIORITY Emergency through signal level Tel...

Page 11: ...ges burns spilt liquids or other substances excessive humidity battery deterioration and internal manipulation of the device the software or its components by unauthorized persons and in general any u...