CONNECTION
make the connections with the amplifier and all the audio system components switched off and disconnected
from the power supply.
Connect the microphones through the miC 1 to 4 inputs and select if you want to activate phantom (for
condenser microphones) or not (dynamic microphones). if you want, you can send announcements to each
zone individually by connecting the m-512 microphone through the REmOTE port.
Connect the audio sources through the liNE 1 or 2 inputs.
if you wish to use the amplifier as just one zone, connect the speakers to the speaker OUTPUT. Use the low
impedance 4 or 8 Ω output or the high impedance 100 or 70 V line output, according to the type of speakers
that you are going to connect. Do not connect both types of output at the same time.
if you use the low impedance output, the speakers must be connected in a series/parallel circuit so that the
speaker load impedance is equal to the amplifier output impedance and the power supplied by the amplifier
does not exceed what is withstood by the speakers.
if you use the high impedance 100 or 70 V line output, you must connect all the speakers in parallel and the
sum of the speaker power must not exceed the power supplied by the amplifier. if you want to use an
amplifier with zones, connect the corresponding speakers to each zone to the corresponding speaker output
ZONE 1 to 5. The speakers must be 100 V line and connect in parallel so that the sum of the power of all the
speakers does not exceed the power supplied by each zone (25 W).
if you want to record the amplifier output or connect it to another system, use the OUT liNE output.
Once the connections have been made according to your needs, connect the equipment to the mains and
switch it on. After use, do not forget to switch it off and disconnect the equipment from the mains.
- 8 -