40
fig. 10
KeY
a Air intake - S Flue gas venting - Condensate - Rain
3.2.6.
Air intake and flue gas venting system
Flue gas discharge into the atmosphere and air intake/flue gas venting systems must comply with applicable laws and standards in the country of
installation that are considered as fully transcribed herein.
The boiler is equipped with safety devices checking correct flue gas exhaustion.
Should an air/flue gas system malfunction occur, the safety devices will shut-down the boiler and the lCd will display the e03
code flashing.
It is strictly forbidden to tamper with and/or prevent operation of such safety devices.
Should the boiler repeatedly shut-down, it is necessary to have air/flue gas system ducts inspected, as they might be obstructed
or inadequate to flue gas discharge into the atmosphere.
for the air intake/flue gas venting systems, specific, manufacturer approved, condensate acid-resistant pipes and systems must
be used, suitable for condensing boilers.
Flue gas venting pipes are to be installed tilted toward the boiler so that condensate runs toward the combustion chamber,
which is designed for condensate collection and drainage.
Should the above procedure not be possible, it is necessary to install, in condensate stagnation areas, devices designed for
condensate collection and conveying to the condensate drain system.
It is necessary to avoid formation of condensate stagnation areas in the flue gas venting system, with the exception of the
condensate trap possibly connected to the venting system itself.
The manufacturer cannot be held responsible for any damage caused by inappropriate boiler installation or operation, modification to
the boiler, or due to non-observance of the instructions provided by the manufacturer or of legislation and standards applicable for the
materials installed.
When positioning the boiler exhaust terminals onto the wall, comply with the distances specified in the applicable standards and regulations in
force in the Country of installation, which are herein considered as entirely transcribed.
Installation examples