EN - 34
6. FACTORY SETTINGS:
allows returning to the factory parameter setting. Select VALIDATE and press and hold the knob for
approx. 5 seconds to reconfigure the factory settings.
7. RESTRICTIONS:
Select this option in the PARAMETERS menu to:
-
Set the maximum permitted temperature: the maximum temperature can be adjusted from 22 to 30 °C, 30 °C is the
factory setting
-
Lock the use of PARAMETERS or the use of both PARAMETERS and PROGRAMMING (PAR & PR). No menu is locked in the
factory settings.
To lock the use of parameters or programming, it is necessary to enter a PIN code.
The PIN code is: 139.
The PIN cannot be changed.
When the limitations have been activated, the PIN is required to access the locked menus.
In the RESTRICTIONS/MENU LOCK menu, the locked function is marked with a dot.
To remove the lock, enter the RESTRICTIONS/MENU LOCK menu and select NONE.
4.6.1 DETAILS OF SOME FUNCTIONS
WINDOW OPENING DETECTION FUNCTION
The radiator is able to identify whether a window has been opened through detection of a quick ambient temperature reduction
(5°C at least in a maximum of 30 minutes). If this happens, the radiator switches off for 30 minutes and then it restarts working
in the previously set mode if it detects a subsequent increase in temperature of at least one degree centigrade (the window has
been closed), otherwise it remains off for an additional 30 minutes.
When the function is activated and the window opening is detected, the displayed symbol of the window flashes.
PILOT WIRE MODE (FOR FRANCE ONLY)
In this mode the radiator is controlled by a remote-control unit.
To use this function, the corresponding parameter must be enabled in the proper menu.
4.7 TIMER
From SIMPLE / PROGRAM menus, press the knob to access the MENU and then select TIMER to adjust/set:
•
The automatic switching to summer/winter time, of enabled/disabled type. The factory setting is: enabled.
•
Adjusting time and date
4.8 INFORMATION
From SIMPLE / PROGRAM menus, press the knob to access the MENU and then select INFO to access the following information:
•
Ambient T.: is the ambient temperature measured by the probe on board the radiator (See also par. 4.6, point 5).
•
Radiator model
•
Software version
•
Radiator consumption in kW/h. The following consumptions are shown:
a.
Daily, for the previous 7 days.
b.
Monthly, for the previous 12 months.
c.
Annual, for the previous 4 years.
d. Total.
PARAM
PAR&PR
LOCKING MENUS
NONE
PARAM
LOCKING MENUS