background image

3.

1. CHARACTERISTICS

1.1 Characteristics of the appliance

IP24: appliance protected against splashing water

 

 Class II: double insulation 

1.2 Technical characteristics of the electronic part

Power supply

23.0V +/-10% AC 50 Hz

Electrical resistor capacity

Mod. SM0805

800 W

Mod. SM1006

1000 W

Mod. SM1509

1500 W

Mod. SM2011

2000 W

Insulation class

Class II

Water protection rating

IP24

Operating temperature

0 to 40°C

Storage temperature

-20 to 80°C

Relative humidity

0 to 85% without condensate

Regulation type

Proportional integral

Temperature range

7° ; 15 to 3.0°C

Activation of safety thermostat

110°C for 800W and 1000W
120°C for 1500W and 2000W

Temperature reading resolution

1/16 °C

Maximum range

0.5 °C

Maximum deviation

1.5 °C

 

 

2. DESCRIPTION AND TECHNICAL SPECIFICATIONS OF THE PRODUCT

The radiator consists of a die-cast body of EN AB 46100 aluminium alloy. 

The inner heating element is an electric resistance embedded between two plates of soapstone. 

Soapstone is a natural material with high inertia capable of storing heat and releasing it slowly even when the radiator is turned off. 

The electronic control and adjustment ensure high precision in adjusting room temperature. 

A safety thermostat limits the maximum temperature which the radiator can reach even in case of failure. 

 

 

   

On the left-hand side there is a receptacle for distilled water used to humidify the environment.

 

 

   

This receptacle can be removed when filling.

NB: All Fondital radiators are manufactured with an identifying label which guarantees their traceability.

This label certifies that the appliance complies with European directives and electrical standards.

The appliance must be installed according to accepted practice, in accordance with current standards and the instructions contained in 

this manual.

Radiator colour: RAL 9010.

Summary of Contents for AL-ADVANCE

Page 1: ...INSTALLATION AND MAINTENANCE MANUAL AL ADVANCE IST 03 F 047 01 EN Inertia oil free electric radiators...

Page 2: ...THE PACKAGE INCLUDES Aluminium radiator fitted with a thermostat with electronic regulation kit made up of three mounting brackets with wall plugs and instruction manual CONTENTS 1 CHARACTERISTICS Pa...

Page 3: ...ts of a die cast body of EN AB 46100 aluminium alloy The inner heating element is an electric resistance embedded between two plates of soapstone Soapstone is a natural material with high inertia capa...

Page 4: ...e or similarly qualified personnel in order to avoid any hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of exp...

Page 5: ...ral du radiateur 800 W 1500 W 2000 W 1000 W A A B B D E D E 6 l ments 9 l ments 11 l ments C E C E B F B F A A 1000 W 5 l ments C D C D 800 W 1500 W 2000 W min 120 mm C C axe central du radiateur axe...

Page 6: ...Screw the two brackets equipped with the locking elements previously secured to the bracket using only one of the two screws 6 Place the radiator onto the brackets 7 Tighten the second screw of the b...

Page 7: ...ng a shunt box located 25 cm from the ground without the use of an electrical plug Never insert metal objects into or attempt to pierce the side of the radiator containing the regulation system right...

Page 8: ...e 12 When the radiator is in clock mode the screen shows the time in the other modes it shows the programmed temperature A small icon indicates the current mode There is an LED light on the control pa...

Page 9: ...2 4 6 8 10 12 14 16 18 20 TL TH THERMOMETER 6 4 Setting times and weekly programming Press the stand by and mode keys at the same time and hold for three seconds A dot will blink on the screen next to...

Page 10: ...segment on the screen and therefore TH as well Pressing the key deactivates the segment and the programmed temperature will be equivalent to the TL level PROGRAMME DAY PROGRAMME HOUR PROGRAMME MIN 0 4...

Page 11: ...ll be selected by the Pilot Wire control centre 6 6 3 Comfort mode This is the normal mode when the radiator is in use keeping the ambient temperature at the programmed level 1 Press the mode key unti...

Page 12: ...in stand by Comfort Comfort status and the temperature which the environment must be kept at are transmitted Night time Night time status and the temperature which the environment must be kept at are...

Page 13: ...th one with greater output Ineffective ambient temperature regulation Err S The temperature sensor is faulty Contact technical support for repair 9 WARRANTY The electrical system of the radiator is gu...

Page 14: ...2003 on waste from electrical and electronic equipment WEEE and in accordance with the following harmonized regulations EN 60335 1 2004 04 safety of electrical equipment for domestic or similar uses P...

Page 15: ...15 Notes...

Page 16: ...878 31 Fax 39 0365 878 576 e mail info fondital it www fondital com The manufacturer reserves the right to modify the products as it deems necessary and useful without affecting their basic features...

Reviews: