5. ELECTRICAL CONNECTIONS
IMPORTANT
During installation, maintenance and cleaning, the appliance must be disconnected from the power supply.
The electronic thermostat must be connected to a 23.0 VAC power supply only. Follow the colours indicated:
Brown
Phase
Blue or grey Neutral
Black
Pilot Wire
Note:
The pilot wire is used only in radiators sold in France.
If the (black) pilot wire is not in use, regulations require that it be isolated. Never connect it to the earth lead for any reason.
A multi-pole circuit breaker must be installed. The distance between the contacts must be at least 3. mm.
The appliance’s power circuit must be protected by a high sensitivity differential protection device.
The power cord must be connected to the power supply using a shunt box located 25 cm from the ground, without the use of an electrical plug.
Never insert metal objects into or attempt to pierce the side of the radiator containing the regulation system (right side).
If the power cord is damaged, it must be replaced by a qualified electrician only.
5.1 Details of bathroom installation
The appliance must be installed according to current regulations and laws in the country of use.
The radiator is class II and has IP24 electrical protection.
In bathrooms, it can be installed in areas 2 and 3. (see figure 1) on condition that the control device is not within reach of people using the shower
or bathtub.
The radiator must not be connected to the earth lead.
In the bathroom, protect the power line with a 30 mA high sensitivity differential device
Install a multi-pole circuit breaker. The distance between the contacts must be at least 3 mm.
2,5 m
Area 0
Area 0
Area 1
Area 2
Area 3
fig. 1
Area types in bathrooms