Dispenser and Ice Machine 230 V/50 Hz, Rear Drain 5
Specifications
Water
WARNING!
— Connect to potable water supply only.
— The discharge drain must be installed via a type AA, AB, or AD air gap or in accordance with
requirements of EN1717 . .
§
Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§
Not recommended for use with softened water
§
Ingress Protection (IP) rating: IPX0 (no protection)
Clearances
§
7 .62 cm (3") behind and on each side of dispenser for electrical connection and ventilation
Electrical
§
E Series: 230 V, 50 Hz, 1 phase, 5A, maximum fuse 10A
§
Connect to dedicated 10A circuit, fuse or breaker .
§
Must be grounded - requires 3-prong outlet . Do not remove ground .
§
Replacement cord instructions, type IEC 60320-C13 attachment - If the supply cord is damaged, it must be
replaced by a special cord or assembly available from the manufacturer or its service agent .
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§
Refrigerant R134a – 204 grams (7 .2 ounces)
Heat Rejection
§
498 W (1700 BTU/hr)