16
Undercounter Dispenser and Ice machine 7UC100A/7UD100A
Service
(continued)
–––––––––––––––––––––––––––––––––––––––––––––––––––
21 . Remove and discard mating ring and seal (Fig . 18 .1) .
22 . Carefully remove auger (Fig . 18 .2) .
WARNING!
Use caution when removing auger. The auger is very
sharp - handle with care to avoid personal injury.
Fig . 18
1
2
Evaporator Assembly
1 . Remove and inspect main housing O-ring seal . Replace if
damaged in any way .
2 . Clean O-ring groove . Lubricate O-ring with Petro-gel and
reinstall .
3 . Use cardboard disc to press new mating ring into main
housing
(Fig . 19 .1) .
4 . Lube the shaft with liquid soap in the area shown
(Fig . 19 .2) and slip on seal and spring (Fig . 19 .3) .
Note: Do not touch the sealing surfaces with bare hands .
Contact with bare skin will cause premature seal failure .
5 . Install auger (Fig . 19 .4) .
Fig . 19
Cardboard
disc
Do NOT
touch!
1
3
4
2
6 . Install main housing:
§
Slide main housing onto auger shaft
(Fig . 20 .1) .
§
Install three M6x25 allen screws
(Fig . 20 .1) .
§
Connect vent line to T fitting
(Fig . 20 .1) .
Fig . 20
1
2
3