12
Undercounter Dispenser and Ice machine 7UC100A/7UD100A
Cleaning and Sanitizing
(continued)
––––––––––––––––––––––––––––––––––––––
Cleaning: User Interface and Exterior Cabinet
1 . Press and release maintenance/clean switch so that only "FRESH FILTERED ICE AND WATER" displays
in the user interface to enter Cleaning Mode (and disable dispensing) .
2 . Plastic parts, including the user interface, can be cleaned with a non-abrasive glass cleaner . Clean
stainless steel panels with stainless steel cleaner .
3 . Press and release maintenance/clean switch to put unit back into service .
Service –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
LED Indicator Description
The LED Indicator is located behind the front panel .
Fig . 10
Clean
PM
Drip tray
W
ater leak
HI press
HI amps
Service
Maint
Low water
Time delay
Sleep cycle
Making ice
Low bin
Power ON
LED Name
LED Color
Description
Clean
Green
The dispenser is in Cleaning Mode . Dispenser is disabled to allow for cleaning of front
panel . See
Maintenance/Cleaning Mode on page 9
.
—
N/A
Not used .
PM
Red
Six-month periodic maintenance required .
Drip tray
Red
Drip tray full .
Water leak
Red
Internal leak in dispenser .
High amps
Red
Auger gearmotor has exceeded 0 .55A . The HI amps and Time delay LEDs will illuminate,
the machine will shut down for one hour, the LEDs will turn off, and the machine will
resume normal operation .
Service
Red
8000 hour bushing check (call Follett technical service group at (877) 612-5086 or
+1 (610) 252-7301) .
Maintenance
Yellow
Enter Maintenance Mode by pressing and holding maintenance/clean switch for 5 seconds .
Unit will not make or dispense ice .
Low water
Yellow
Insufficient water supply to machine or no low bin LED upon startup .
Time delay
Yellow
Ice production will not resume for at least 15 minutes after a full bin is achieved and a
minimum amount of dispense activity has elapsed .
Sleep cycle
Green
After a full bin and 10 minutes of non-use, the unit goes into standby and will not produce
ice until either 12 hours has elapsed or ice or water has dispensed .
Making ice
Green
Gearmotor, compressor, and fan motor energized .
Low bin
Green
Bin switch closed calling for ice .
Power on
Green
Power supplied to unit .