Undercounter Dispenser and Ice machine 7UC100A/7UD100A 15
Service
(continued)
–––––––––––––––––––––––––––––––––––––––––––––––––––
15 . Remove M6 socket head allen screw (Fig . 15 .1) .
16 . Remove compression nozzle retainer (Fig . 15 .2) .
17 . Remove compression nozzle (Fig . 15 .3) .
Fig . 15
2
1
3
18 . Remove main housing:
§
Disconnect vent line from T fitting
(Fig . 16 .1) .
Fig . 16
1
19 . Remove three M6x25 socket head allen screws
(Fig . 17 .1) .
20 . Remove main housing (Fig . 17 .2) .
Fig . 17
1