Focus SKY-5A Assembly And Maintenance Instructions Download Page 9

ON/OFF:    

1.

Press ”on/off” to start up, and then press ”on/off” to shut down.

WIND:

1.

Press the swing wind button to start the swing wind function; Press the swing button again, and the left and right swing function will be 
cancelled.

TEMP-:

1.

Under cooling and heating function, set in the range of 17 - 30°C in cooling mode and 15 - 25 °C in heating mode. Every click on the 
temperature, set temperature reduced by 1 °C.

TEMP+: 

1.

Under cooling and heating function, set in the range of 17 - 30°C in cooling mode and 15 - 25 °C in heating mode. Each press keys on 
temperature, set temperature increase 1 °C.

MODE:    

1.

Press the mode key to perform mode conversion and select one of the operation modes of ”refrigeration, dehumidification, air supply, 
heating , and automation”.

1.1. Cooling  operation:  Press  the  mode  key  until  the  refrigeration  indicator  is  on,  and  select  the  refrigeration  function.  While  the 
refrigeration function is in progress, extend the bar Put the tube out of the window so that hot air can escape from the room. According to 
the temperature rise or lower key can adjust the set temperature, the temperature range of 17-30 °C / 63 ~ 86 °F. Press the wind speed 
button to select one of the high, medium and low wind speeds. 

Note:

 In order to improve the cooling capacity of the machine, please note 

the  following: A) if the room is in direct sunlight, please close the curtains. B) do not place the machine where there is a heat source. 

Depending on the rate of in which room is heating up and its size it might be not possible to cool it down to selected temperature.

1.2. Dehumidifying operation: Close the doors and Windows when using the machine to prevent excess moisture from entering the 
room.  Press  the  mode  key,  the  dehumidification  indicator  will  light  up,  and  the  display  screen  will  display  dH,  and  select  the 
dehumidification function. In this mode, the wind speed is not adjustable, the default low speed. In the case of selecting dehumidification 
mode, expansion tube is not required.

1.3. Fan operation: Press the mode key, the display will display FA, and select the function of air supply. Press the wind speed button to 
select one of the high, medium and low wind speeds.

1.4. Heating operation: Keep pressing the mode key until the heating light is on. Press the ”+” or ”-” key to choose their own need to 
temperature, temperature range of 15-25 °C / 59 ~ 77 °F. 

Note: 

Depending on the rate of in which room is cooling down and its size it 

might be not possible to heat it up to selected temperature.

Temperature display conversion:

1.

Press both the temperature - and + keys, and the display will switch between Fahrenheit and Celsius.

TRYB CIĄGŁEGO OPRÓŻNIANIA ZBIORNIKA / CONTINUOUS DRAINAGE

1.

W trybie osuszacza należy wyjąc gumowy korek z otworu (A). Następnie zamontować wąż spustowy do otworu spustowego. Z tego 
trybu można również korzystać w trakcie używania innych funkcji klimatyzatora.

1.

In dehydration mode pull out the rubber water plug inside

 (A)

. Next nstall the drain pipe on the drain changer. This mode can be also used 

in other air conditioner working modes.

9

Summary of Contents for SKY-5A

Page 1: ...ONS PORTABLE AIR CONDITIONER SKY 5A PL Nale y sprawdzi wszystkie elementy przed monta em Nie nale y montowa produktu w przypadku stwierdzenia uszkodze kt regokolwiek z jego element w EN All elements s...

Page 2: ...y the details that are necessary for correct assembly of the product ATTENTION Failing to follow recommendations included in these instructions may be the basis for rejecting a possible claim UWAGI OD...

Page 3: ...ected with maintenance of the device 2 Before connecting the device check whether the voltage of the mains supply is in accordance with the parameters given on the rating plate 3 The device cannot be...

Page 4: ...m2 Do not cover the device 8 The appliance must be stored and used in such a way as to prevent mechanical failure 9 Individuals who operate or work on the refrigerant circuit must have the appropriate...

Page 5: ...n the picture WARNING Window kit is designed to be mounted in sliding windows ZALECENIA DOTYCZ CE MONTA U RURY WYLOTOWEJ RECOMMENDATIONS ON INSTALLING EXHAUST PIPE By zapewni najwy sz efektywno pracy...

Page 6: ...z sto automatycznie wy cza Je li to nast pi to nale y przestawi urz dzenie w bardziej optymalne miejsce pracy 2 Przed pod czenie urz dzenia do gniazdka upewni si e nie jest ono uszkodzone Nale y si te...

Page 7: ...b dzie dzia a z nisk pr dko ci 1 2 Je li jest ona wy sza o 2 4 C w stosunku do temperatury ustawionej to wentylator b dzie dzia a ze redni pr dko ci 1 3 Je li jest ona wy sza o wi cej ni 4 C w stosun...

Page 8: ...wind speed will be locked in low wind Note in heating mode the wind speed cannot be adjusted The wind speed will be locked in high wind Note Automatic mode works only in cooling and fan operation mod...

Page 9: ...ending on the rate of in which room is heating up and its size it might be not possible to cool it down to selected temperature 1 2 Dehumidifying operation Close the doors and Windows when using the m...

Page 10: ...budowy przed ich wyczyszczeniem Filtr demontuje si zgodnie z rysunkiem By go ponownie zamontowa nale y wsun go na swoje miejsce w obudowie Nie nale y ich zamienia miejscami Nie nale y montowa wilgotny...

Page 11: ...ON LINE i post powa zgodnie instrukcjami wy wietlaj cymi si na ekranie pisemnie na adres Gwaranta NOVOTERM Sp z o o ul Zimowa 6 70 807 Szczecin 9 W razie stwierdzenia w okresie gwarancji wady produkt...

Page 12: ...AWY GWARANCYJNEJ US UGI SERWISOWEJ Lp Data Opis wykonanych czynno ci Podpis i piecz firmy dokonuj cej czynno ci 1 2 3 4 5 12 c h o o s e c o m f o r t Producent Manufacturer NOVOTERM Sp z o o ul Zimow...

Reviews: