background image

INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MODELS COVERED BY THESE INSTRUCTIONS

PI27 BLENHEIM 
PI27 ENVY 
P127 HORIZON
P127 LULWORTH

INSET FLUELESS GAS FIRE

1

Revision G - 02/13

©

2013 Focal Point Fires plc.

The products covered by this booklet are protected under

patent GB2275331C.

GB IE

BS EN 14829 : 2007

KM579167

MODEL SHOWN: BLENHEIM INSET FLUELESS

Focal Point Fires plc.

Christchurch, Dorset BH23 2BT

Tel: 01202 499330     

Fax: 01202 499326

www.focalpointfires.co.uk

e : [email protected]

Please  note  :  Except  where  otherwise  stated,  all  rights,

including copyright in the text, images and layout of this

booklet is owned by Focal Point Fires plc.  You are not per-

mitted to copy or adapt any of the content without the

prior written permission of Focal Point Fires plc. 

IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE

Questions or problems with your appliance?

Don’t take it back to the store

just give us a call on 

01202 588601

we’re here to help

lines open between 9am and 5pm, Monday to Friday

Summary of Contents for P127 HORIZON

Page 1: ...2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e sales focalpointfires co uk Please note Except where otherwise stated all rights including copyright in the text images and layout of...

Page 2: ...und heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning off of hig...

Page 3: ...ation of the fire This volume may include adjacent spaces but these spaces must not be separated by a door To calculate a room size in cubic metres m3 divide the room volume in cubic feet ft3 by 35 3...

Page 4: ...to support the base of the appliance and decora tive facia In this situation the thickness of the hearth or ledge may be as desired but it must have the strength to support the weight of the appliance...

Page 5: ...g with their installation If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to support the appli ance e g so it can...

Page 6: ...e should always be sleeved through walls and floors using the shortest possible route For concealed supply pipe routing pipes must where possible be vertical and providing there is sufficient wall thi...

Page 7: ...lly under a block joint Clear out the block work in the area and insert the lintel by saw or stitch drill and chisel Do not dry bed the lin tel always bed on mortar and securely slate pin Clear out th...

Page 8: ...with out excessive heat loss from the room when the fire is off Installation as per method 2 recessing into a wall When setting the appliance into the wall find a suitable position between frame timbe...

Page 9: ...e opening and guide the gas pipe through the sealing grommet into its final routing position and fit the restrictor inlet elbow supplied to the gas pipe Secure the firebox by inserting screws in the p...

Page 10: ...n 7 3 All models The gap between the spark electrode and the pilot should be 3 5 4 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric spar...

Page 11: ...turning anti clock wise to the high position The main burner should light after a few seconds To decrease the setting to LOW push the knob in slightly and turn the control knob clockwise to the low se...

Page 12: ...d check operating pressures 17 Carry out combustion check as per section 9 4 18 Check safe operation of the appliance For specific servicing instructions see relevant sections Remove the fire front an...

Page 13: ...on monoxide CO concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbo...

Page 14: ...re is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughl...

Page 15: ...d soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See relevant section for further details on clearances to combus...

Page 16: ...such as metal heat deflec tors but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution Under no circumstances should any electrical equipmen...

Page 17: ...ng push the control knob in slightly and continue turning anti clock wise to the high position The main burner should light after a few seconds To decrease the set ting to LOW push the knob in slightl...

Page 18: ...either be cleaned using a proprietory metal cleaner or baby oil Test on a small hidden part before cleaning Always clean in the direction of the grain The appliance should be checked on an annual basi...

Page 19: ...s easy If you wish to make a claim under our 3 year guarantee and all the terms and conditions for your product have been met then please submit the following information for the attention of the 3G S...

Reviews: