background image

BRIEFING THE CUSTOMER

All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire.
After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the
need for regular servicing.  Frequency of service depends on usage, but MUST be carried out at least once annu-
ally.

Advise that cleaning of the fire maybe achieved when the fire is cold using a damp cloth and mild detergent on
most surfaces. Advise that the fire will emit a "newness" smell for a time after initial commissioning and that extra
ventilation may be needed during this time.  Recommend that a guard be used for the protection of the young,
pets, the elderly and the infirm

SERVICING

Isolate the fire from the gas supply.  Ensure that the fire is fully cold before attempting service.  
A suggested procedure for servicing is detailed below.

1. Lay out the dustsheet and tools.
2. Remove the decorative frame/glass facia assembly. Removal is reverse of section 8.4.
3. Remove the glass door assembly (4 screws) and clean carefully.
4. Inspect the burner and the catalyst and clean if necessary with a soft brush.
5. Disconnect the gas supply.
6. Detach the burner front cover plate by removal of the four retaining screws. Undo the four 

screws retaining the burner support brackets to the base and rear of the firebox. Remove the 
control knob and spindle assembly from the valve by removal of the spindle retaining clip.

7. Remove the burner unit, strip off the burner pipes and clean thoroughly.
8. Clean the in-line restrictor, pilot assembly and the burner tube. Do not attempt to remove the 

pilot injector as this can cause damage.

9. Re-assemble components.
10. Turn on the gas supply and leak test. Check pilot and burner for good ignition.
11. Refit the glass door assembly, ensuring correct orientation and a good seal.
12. Refit the decorative facia/frame assembly as detailed in section 8.4. 
13. Check the purpose provided ventilation is un-obstructed.
14. Light the fire and test setting pressures.
15. Check safe operation of the appliance. 

For specific servicing instructions, see relevant sections.

SERVICING THE BURNER UNIT AND GAS ASSEMBLY

Firstly, remove the decorative glass facia assembly as described in section 8.4. Remove the inner glass panel, and
disconnect the gas connection inside appliance. The gas connections to the gas valve can now be released.
Detach the burner front cover plate by removal of the four retaining screws. Undo the four screws retaining the
burner support brackets to the base and rear of the firebox, and remove the control knob and spindle assembly
by removal of the spindle retaining clip. The burner may now be removed.
Remove the pilot and main burner pipes and blow through to dislodge any debris. Now remove the restrictor
elbow and blow through to make sure it is entirely clear. 

Unclip the pilot lint gauze and clean with a soft brush. Clean the exterior of the pilot assembly with a soft brush
and blow through the flame ports on the pilot head. Check the aeration holes are free from lint or dirt. The pilot
assembly can be removed if required by disconnecting the electrode HT lead, gas pipe and unscrewing the
mounting screws and lifting away. 

The pilot assembly is a non-serviceable item and should not be taken apart.  Aeration holes must be absolutely
clear internally for proper operation. 

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT

STAY ALIGHT

. Modifications are dangerous and can have serious unseen effects on safety. If the pilot will not

stay lit there is a problem with dirt, the gas supply to it,  or the thermocouple needs replacement. 

The gas valve is a non-serviceable item. If this needs replacement, remove M4 securing screw holding the valve
in place, remove all pipe unions, electrode lead, thermocouple lead and then the complete valve. Replacement
must be original manufacturers parts. Re-assembly is the reverse of removal. Ensure setting pressures are as stat-
ed in Section 2; Appliance Data.

8

10.0

9.0

10.1

Summary of Contents for L23 BLACK

Page 1: ...ser for safekeeping Revision A 03 08 Country s of destination GB IE L23 CHESHIRE P23 MONET TRIO P23 ENIGMA FLUELESS GAS FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 012...

Page 2: ...L23 Cheshire P23 Monet trio P23 Enigma silver glass...

Page 3: ...fire This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume in ft3 by 35 3 This app...

Page 4: ...only in a sufficiently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility...

Page 5: ...is common however other rooms such as kitchens dining rooms and hallways are permitted providing a suitable natural gas supply is available and rooms sizing and ventilation requirements are strictly a...

Page 6: ...s etc be positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should b...

Page 7: ...met 1 Fitting template GAS SUPPLY ROUTES There are four possible entry points for the gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas c...

Page 8: ...p wall plugs taking care to leave the screws protruding approximately 5mm from the wall Now hang the appliance onto these screws through the two key hole shaped holes in the back panel of the applianc...

Page 9: ...If under any circumstances the piezo electric spark fails the pilot cannot be lit man ually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burne...

Page 10: ...ve packaging The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing Ensure each screw is unscrewed approxi mately one turn from the fully screwed in pos...

Page 11: ...detailed in section 8 4 13 Check the purpose provided ventilation is un obstructed 14 Light the fire and test setting pressures 15 Check safe operation of the appliance For specific servicing instruct...

Page 12: ...ed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per m...

Page 13: ...tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If th...

Page 14: ...dicator bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fi...

Page 15: ...dis colouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materials of any kind This dimension is measured vertically to the...

Page 16: ...y device ODS If the appliance shuts down during use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbance could be...

Reviews: