INSTALLATION AND USER INSTRUCTIONS

All instructions must be handed to user for safekeeping

Revision A - 03/08

Country(s) of destination - GB/IE

L23 CHESHIRE

P23 MONET TRIO

P23 ENIGMA 

FLUELESS GAS FIRE

Focal Point Fires plc, Christchurch, Dorset BH23 2BT

Tel: 01202 499330     Fax: 01202 499326

www.focalpointfires.co.uk

e-mail: [email protected]

Summary of Contents for L23 BLACK

Page 1: ...ser for safekeeping Revision A 03 08 Country s of destination GB IE L23 CHESHIRE P23 MONET TRIO P23 ENIGMA FLUELESS GAS FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 012...

Page 2: ...L23 Cheshire P23 Monet trio P23 Enigma silver glass...

Page 3: ...fire This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume in ft3 by 35 3 This app...

Page 4: ...only in a sufficiently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility...

Page 5: ...is common however other rooms such as kitchens dining rooms and hallways are permitted providing a suitable natural gas supply is available and rooms sizing and ventilation requirements are strictly a...

Page 6: ...s etc be positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should b...

Page 7: ...met 1 Fitting template GAS SUPPLY ROUTES There are four possible entry points for the gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas c...

Page 8: ...p wall plugs taking care to leave the screws protruding approximately 5mm from the wall Now hang the appliance onto these screws through the two key hole shaped holes in the back panel of the applianc...

Page 9: ...If under any circumstances the piezo electric spark fails the pilot cannot be lit man ually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burne...

Page 10: ...ve packaging The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing Ensure each screw is unscrewed approxi mately one turn from the fully screwed in pos...

Page 11: ...detailed in section 8 4 13 Check the purpose provided ventilation is un obstructed 14 Light the fire and test setting pressures 15 Check safe operation of the appliance For specific servicing instruct...

Page 12: ...ed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per m...

Page 13: ...tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If th...

Page 14: ...dicator bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fi...

Page 15: ...dis colouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materials of any kind This dimension is measured vertically to the...

Page 16: ...y device ODS If the appliance shuts down during use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbance could be...