Data badge
On the right hand side of the oven, behind the oven door.
Type of gas
This cooker must only be used with LPG only, as specified on the appliance data badge.
Pressure test point
Use the oven injector
Aeration - Fixed
Electrical supply/Load
220 - 240V ~ 50Hz
37 Watts
Spark generator: Mains operated 6 outlet controlled by a single button at the left hand side of the facia to individual
electrodes. 2 outlets shorted to earth.
Warning: This cooker must be earthed.
Hob - Burners have heads and caps which are removable for cleaning, note position of concealed electrodes.
2.0 ENVIRONMENTAL
GB IE
NOTE: Before discarding an old appliance, switch off and disconnect it from the power supply. Cut off and render any plug unusable.
Cut the cable off directly behind the appliance to prevent misuse. This should be undertaken by a competent person. Disable any door
lock to make sure that children cannot get trapped inside the appliance.
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment, human
and health, which could otherwise be caused by inappropriate waste handling of this appliance.
The symbol shown in figure 1 on the product or on the documents accompanying the product indicates that this appliance may not
be treated as household waste. Instead it shall be handed over to the applicable collection point for recycling of electrical and elec-
tronic equipment.
Disposal must be carried out in accordance with the local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of this product, please contact your local authority household
waste disposal service or the shop where you purchased the product.
Your safety is of the utmost importance to FOCAL POINT.
Please make sure that you read this instruction booklet before attempting to install or use the appliance. If you are unsure of any of
the information contained in this booklet, please phone the FOCAL POINT advice line.
IMPORTANT: Any installation work must be carried out by a gas safe registered installer, a qualified electrician or competent per-
son.
Use of the appliance
Your appliance is only designed to be used in the home. It is not suitable for storing food. If it is used for any other pur-
pose or it is not used correctly, FOCAL POINT will accept no liability for any damage that may be caused.
Altering the specifications of the appliance must not be attempted for reasons concerning your safety.
Before using the appliance
Check the appliance for any signs of transport damage. If you notice any damage then you should not connect the appliance
to the main power supply, also contact the manufacturer.
3
© 2018 Focal Point Fires plc.
3.0 APPLIANCE DATA
Model Destination
Country
Cat
Gas
Type
Operating/Inlet
Pressure (±2.0 mbar)
Small Medium Large Oven
Grill
BI600SS
B1600S1
BI600BL
GB - IE
II2H3+
G30
G31
28 - 30mbar
37mbar
Hi 0.81kW 1.44kW 2.61kW 2.12kW 1.22kW
Hs 0.90kW 1.60kW 2.90kW 2.35kW 1.35kW
Injector mm
0.50
0.65
0.85
0.72
0.60
figure 1