Operation Manual EMGZ490A
30.08.2019
19
6.3
Acyclic Data Traffic
After a successful system boot the IO-controller and associated IO-devices can start
exchanging acyclic data. The table below shows which parameters and instructions are
transmitted.
In
de
x
Access M
ode
1)
Parameter
Instruction
Data
Type
Range
Da
ta
F
or
m
at
Uni
t
Description
0x01
R
Device-ID unsigned
int
(unsigned
16 Bit)
0
to
65535
#0 - Request
Device Type
0x02 R
Version
unsigned
int
(unsigned
16 Bit)
1
to
10000
#0.00
-
Request
Firmware Version
0x10 R/W Low pass filter
feedback
active(PROFIN
ET)
byte
(unsigned
8 Bit)
0
bis
1
0 -
Switch
filter
on/off
0 = off; 1 = on
Non-remanent:
the set value will
be lost after each
re-start
0x11 R/W Low pass filter
Analogue
Output active
byte
(unsigned
8 Bit)
0
to
1
0
-
Switch filter
on/off
0 = off; 1 = on
Non-remanent:
the set value will
be lost after each
re-start
0x20 R/W Offset
int
(signed 16
Bit)
±8‘000 #0 - Offset
0x21 R/W Gain
unsigned
int
(unsigned
16 Bit)
0
to
20000
#0.000 -
Gain
0x22 R/W System
Force unsigned
long
(unsigned
32 Bit)
0
to
200‘000‘000
#0.000 N
The system force
is the maximum
permissible force
in the measuring
system