www.fmiproducts.com
112108-01F
24
8. Take twigs “C” (shaped like a “Y”) and place
them as shown in Figure 47.
9. Take twigs “D” (bent twig) and place them
as shown in Figure 47.
10. Place twig “E” across the top of logs “B” as
shown in Figure 47.
11. When finished installing logs, close glass
door. Make certain safety door switch is fully
depressed by door frame before securing four
(4) spring loaded latches.
12. Replace louvers in reverse order with grilles
pointing in down position.
WARNING: Improper installa
-
tion, adjustment, alteration, ser
-
vice, or maintenance can cause
injury or property damage. Refer
to this manual. For assistance or
additional information, consult
a qualified installer, service
agency, or gas supplier.
INSTALLATION
Continued
Left
Front
Right
Back
B
B
A
A
Figure 46 - Installing Logs “B ” (Top View)
Left
Right
Back
Front
D
C
C
D
E
Figure 47 - Installing Twigs “C, D, E ”
(Top View)
DECORATIVE FACING
Any noncombustible material may be used for
facing (glass, tile, brick, etc.) as long as proper
clearances are observed (see
Clearances
, page
6).
IMPORTANT:
Louvered openings must not
be obstructed, and upper and lower panels must
remain removable for servicing. Use only heat-
resistant, noncombustible mortar or adhesive when
securing facing material.
Note:
Combustible material, such as wood, that
has been fireproofed is not considered noncom
-
bustible.
Figure 48 - Correct Pilot Flame Pattern
1/8"
1/2" - 3/8"
PILOT/ELECTRODE
ASSEMBLY ADJUSTMENT
Pilot assembly is factory preset for proper flame
height. Alteration to these settings may have oc-
curred during shipping and handling. If this is the
case, some minor adjustment may be necessary
and should be done by a qualified technician. To
access pilot assembly, glass door must be opened.
Proper settings for thermopile height should be at a
distance of 1/2" to 3/8" from pilot flame as shown
in Figure 48.