www.fmiproducts.com
112108-01F
18
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 29 - Vertical Rigid Venting
Configuration With No Horizontal Run
Vertical Venting
V = 40' max.
HIGH ALTITUDE INSTALLATION
Your FMI PRODUCTS, LLC direct-vent fireplace
has been tested and approved for elevations from
0-2,000 feet and certified for elevations from
0-5,000 feet.
Fireplaces for High Altitude (models ending in
HA) are for installation above 4,000 feet only.
These fireplaces are equipped with parts specific
for higher altitudes.
IMPORTANT
:
These fire
-
places can NOT be converted to propane/LP gas.
When installing a non-high altitude fireplace at
an elevation above 2,000 feet, you may need to
decrease the input rating by changing the existing
burner orifice to a smaller size. Reduce input 4%
for each 1,000 feet above sea level. Check with
your local gas company for proper orifice size
identification.
Consult with your local gas company to help de-
termine the proper orifice size and identification
for your location.
Components and parts must be ordered by part
number through your local dealer or distributor.
IMPORTANT:
For horizontal installations
above 2,000 feet, it is recommended that a 12"
extension pipe be added before starter elbow
(see Figure 30).
PARTS LIST FOR FMI PRODUCTS, LLC
VENTING KITS AND COMPONENTS
FMI PRODUCTS, LLC (5"/8") Pipe & Vent Kits
Number
Description
VKR-58 Roof Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Flue Restrictor,
Vertical High Wind Termination,
2' Pipe, 4' Pipe, Wall Firestop,
Storm Collar, Roof Flashing
[0/12 - 6/12], 26 Screws)
VKB-58 Basement Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
4' Pipe, 90° Elbow, 20 Screws)
VKS-58 Snorkel Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
36" Snorkel Termination, 4' Pipe,
1' Pipe, 90° Elbow, 26 Screws)
VKG-58 Ground Floor Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
16 Screws)
P58-48
48" Section Double Wall Pipe,
Galvanized
P58-36
36" Section Double Wall Pipe,
Galvanized
P58-24
24" Section Double Wall Pipe,
Galvanized
P58-12
12" Section Double Wall Pipe,
Galvanized
P58-6
6" Section Double Wall Pipe,
Galvanized
PA58-712 Adjustable 7"-12" Section Double
Wall Pipe, Galvanized
FPA58-6 6" Dura Vent Collar to FMI Pipe
Adaptor
Figure 30 - Recommended 12" Extension
for High Altitude Installation
45° Starter
Elbow
Note
: Install
restrictor into inner
collar of fireplace
as shown.
45° Starter
Elbow
12"
Extension