www.fmiproducts.com
126333-01A
13
Electrical
Bushing
Electrical
Cover
Plate
Rocker
Switch
Figure 11 - Fan Switch-Electrical Bushing
Electrical
Housing
Wire Nut (3x)
(Not Supplied)
Outer Wrapper
of Fireplace
Electrical Cover
Plate and
Electrical Bushing
Fireplace Chassis
Ground
To Power
Source
Receptacle
(Supplied)
Power Source Wiring
(Not Supplied)
Prewired Receptacle
and Ground
Sheet
Metal
Screws
INSTALLATION
Continued
Decide which way you intend to gain access
into the bottom rear of the firebox to install the
blower accessory. The lower front panel can
be removed easily by snapping out the front
with a flat blade screwdriver. Use caution not
to scratch any surfaces. Models with louvered
front panels can also be removed by inserting
fingertips between slots and gently pulling out.
DO NOT FORCE. The panels are actually
held in place by means of a retention dimple
embossed on the edge of removable panels.
Accessibility to the bottom on 36" and 42"
models only, can also be gained through the
access cover plate on the bottom front of the
firebox hearth. Remove the screws to expose
the rectangular shaped access panel (see
Figure 12). The sides and back refractory
brick liner pieces do not have to be removed
(if installed). Lift access panel out by using
finger holes. Blower accessory BK can now
be installed.
Figure 12 - Removing Access Cover Plate
Access
Cover Plate
Screws
Duplex Electrical Outlet
Figure 13 - Accessing Duplex Electrical
Outlet Installed in Bottom Right Side of
Firebox
WARNING: If there is a duplex
electrical outlet installed in the
right side of the bottom of the
fireplace base area (see Figure
13), be sure that the electrical
power to the outlet is turned off
before proceeding with blower
installation. Failure to do this
may result in serious injury.