www.fmiproducts.com
126333-01A
12
INSTALLATION
Continued
INSTALLING OPTIONAL BLOWER
ACCESSORY
NOTICE:
The firebox identifica
-
tion label (including model num
-
ber, serial number, clearances,
etc.) is located in the right side
screen pocket area on the front
of the firebox. See Figure 19,
page 17.
NOTICE
: If a log set is installed
in the firebox, disconnect log
set from gas supply and remove
from firebox. Contact a qualified
service person to do this.
Note: Appearance of firebox may vary de
-
pending on model.
There is one (1) blower accessory option
for use with this fireplace. Blower accessory
model BK . Model BK is a rotary squirrel cage
type blower with magnetic attachment and
variable speed control.
Wiring Instructions
1. Remove electrical cover plate with bush
-
ing from fireplace by removing 2 sheet
metal screws as shown in Figure 11, page
13.
2. Slide power source wiring through electri
-
cal bushing opening and electrical cover
plate and make all necessary connec-
tions.
3. Slide all wiring connections in electrical
housing as shown in Figure 11, page 13.
4. Secure electrical cover plate with screws
previously removed.
Note: Electrical housing and cover plate have
sharp edges. Wear protective gloves.
Figure 10 - Location of Knockout for
Gas Line
1/2" Thick Liner
Side View
Firebrick Side Wall
Knockout
Remove
This Area
USING OPTIONAL FIBER PANELS
There is a gas knockout in each side panel
for the gas line to feed through. Determine on
which side the gas connection will be located.
Using a utility knife or cutting blade, remove
the identified gas knockout.
CAUTION: Do not use ex-
cessive force to remove the
knockout. Too much force may
damage the fiber panel.