OPTIONAL GAS LINE INSTALLATION
Figure 21 - Gas Line Knockout
6LGH
)LUHEULFN
)LQLVKHG
6LGH
5HIUDFWRU\
.QRFNRXW
3OXJ
2XWVLGHRI
)LUHSODFH
*DV/LQH
&RQGXLW
,QVXODWLRQ
*DV
&RQGXLW
&RYHU
'RZHO
*DV OLQH KRRN XS VKRXOG EH GRQH E\ \RXU
VXSSOLHURUDTXDOL¿HGVHUYLFHSHUVRQ
Note: Before you proceed, make sure your
gas supply is turned off.
8VHRQO\DEODFNLURQSLSHDQGDSSURSUL
-
DWH¿WWLQJV
5HPRYHNQRFNRXWLQGHQWDWLRQRQUHIUDFWR
-
U\RU¿UHEULFNZDOOORFDWHGDERYHUHIUDFWRU\
KHDUWK ÀRRU .QRFNRXW LQGHQWDWLRQ PXVW
EH ¿UPO\ WDSSHG ZLWK DQ\ VROLG REMHFW
VXFKDVDGRZHOXQWLOLWLVUHOHDVHG
5HPRYHIUDJPHQWHGSRUWLRQVRIUHIUDFWRU\
VHH)LJXUH
5HPRYHJDVOLQHFRYHUSODWHORFDWHGRQ
HLWKHUVLGHRI¿UHSODFHDQGSXOORXWLQVX
-
ODWLRQIURPJDVOLQHFRQGXLWVOHHYH6DYH
LQVXODWLRQIRUUHXVH
5XQDEODFNLURQJDVOLQHLQWR¿UH
-
SODFH WKURXJK UHDU DW JDV OLQH FRQGXLW
VOHHYH LI XVLQJ D UDLVHG SODWIRUP DGG
KHLJKW 3URYLGH VXI¿FLHQW JDV OLQH LQWR
¿UHSODFHFKDPEHUIRU¿WWLQJFRQQHFWLRQ
VHH)LJXUH
Note: Secure incoming gas line to wood
framing to provide rigidity for threaded
end.
5HSDFNLQVXODWLRQDURXQGJDVOLQHDQGLQWR
VOHHYHRSHQLQJ6HDODQ\JDSVEHWZHHQ
JDVOLQHDQGUHIUDFWRU\NQRFNRXWKROHZLWK
UHIUDFWRU\FHPHQWRUFRPPHUFLDOIXUQDFH
FHPHQW,QVWDOOJDVDSSOLDQFHRUFDSRII
JDVOLQHLIGHVLUHG
CAUTION: All gas piping and
connections must be tested for
leaks after installation is com-
pleted. After ensuring that gas
valve is on, apply soap and water
solution to all connections and
joints. Bubbles forming show a
leak. Correct all leaks at once.
DO NOT USE AN OPEN FLAME
FOR LEAK TESTING AND DO
12723(5$7($1<$33/,$1&(
IF A LEAK IS DETECTED. LEAK
TESTING SHOULD BE DONE
%< $ 48$/,),(' 6(59,&(
PERSON.
Note: A FMI PRODUCTS, LLC hood must be
installed when using an unvented gas log set
(see Accessories on page 18).
WARNING: Do not operate an
XQYHQWHGJDVORJVHWLQWKLV¿UH
-
place with chimney removed.
,I \RX LQVWDOO D GHFRUDWLYH JDV DSSOLDQFH
YHQWHG JDV ORJ GHFRUDWLYH JDV DSSOLDQFH
PXVWFRPSO\ZLWKWKH
Standard for Decorative
Gas Appliance for Installation in Solid Fuel
Burning Fireplaces, ANS Z21.60, Z21.84
and
VKDOODOVREHLQVWDOOHGLQDFFRUGDQFHZLWKWKH
National Fuel Gas Code, ANSI 7223NFPA 54
latest edition
WARNING: To avoid the risk
RIGDPDJLQJ¿UHSODFHPDWHULDOV
and increasing the risk of spread-
LQJD¿UHGRQRWXVH¿UHSODFHWR
cook or warm food.
6HDO
2SHQLQJ
ZLWK
5HIUDFWRU\
&HPHQW
2XWVLGHRI
)LUHSODFH
*DV
/LQH
&RQGXLW
5HSDFN
,QVXODWLRQ
,QFRPLQJ
%ODFN
,URQ3LSH
6LGH
)LUHEULFN
)LQLVKHG
6LGH
3URYLGH(QRXJK7KUHDGHG
(QGIRU)LWWLQJ&RQQHFWLRQ
Figure 22 - Gas Line Installation