www.fmiproducts.com
56131L
31
ELECTRONIC SYSTEM
E
A
O
L
H
I
L
PI OT
Inlet
Pressure
Figure 60 - Electronic Control Valve
Outlet
Pressure
Flame
Adjustment
Knob
From Gas
Supply
To
Main
Burner
Figure 61 - Electrode
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information
page 30.
2. Set thermostat to lowest setting (if ap-
plicable).
3. Turn off wall switch.
4. Open control access panel or louver.
5. Smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the
safety information, page 30. If you don’t
smell gas, go to the next step.
6. The electrode is located by main burner.
7. Turn main burner wall switch to the ON
position for ignition. There will be a spark
at the electrode.
8. Replace control access panel or louver
once there is a flame at the burner.
• If burner will not stay lit after several
tries, flip wall switch to OFF and call your
service technician or gas supplier.
OPERATION
Continued
SPECIFICATIONS
(V)DVF36TPNA-A(-HA),
(V)DVF36TSTA-A(-HA)
• Input Rating: 35,000/23,300 Btu/Hr
• Fuel: Natural Gas
• Manifold Pressure: 3.5" W.C.
• Minimum Supply Pressure: 4.5 W.C. **
• Maximum Supply Pressure: 10.5" W.C.
• Orifice Size (0-4500 ft.): #34 DMS
(V)DVF36TPNPEA-A,
(V)DVF36TSTEA-A
• Input Rating: 35,000 Btu/Hr
• Fuel: Natural Gas
• Manifold Pressure: 3.5" W.C.
• Minimum Supply Pressure: 4.5 W.C. **
• Maximum Supply Pressure: 10.5" W.C.
• Orifice Size (0-4500 ft.): #34 DMS
(V)DVF36TPNPA-A(-HA),
(V)DVF36TSTPA-A(-HA)
• Input Rating: 31,500/20,000 Btu/Hr
• Fuel: Propane/LP Gas
• Manifold Pressure: 10" W.C.
• Minimum Supply Pressure: 11 W.C. **
• Maximum Supply Pressure: 13" W.C.
• Orifice Size (0-4500 ft.): #51 DMS
(V)DVF36TPNPEA-(A),
(V)DVF36TSTPEA-(A)
• Input Rating: 31,500 Btu/Hr
• Fuel: Propane/LP Gas
• Manifold Pressure: 10" W.C.
• Minimum Supply Pressure: 11 W.C. **
• Maximum Supply Pressure: 13" W.C.
• Orifice Size (0-4500 ft.): #51 DMS
**For purpose of input adjustment.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electrical power to appliance
if service is to be performed.
2. Remove control access panel or louver.
3. Close gas valve.