This fireplace must be installed by a qualified
(certified or licensed) service person. It has
a sealed gas combustion chamber that uses
a millivolt gas control valve with a millivolt
ignition system.
Models (V)DVF36TPNA/TPNPA series are
three-sided direct-vent gas fireplaces and
models (V)DVF36TSTA/TSTPA are two-sided
direct-vent gas fireplace fireplaces with sealed
combustion chambers.
Models (V)DVF36TPNEA/TPNPEA and (V)
DVF36STEA/TSTPEA use a direct spark
ignition with a 24 VAC control module. All
models have HI/LO valve that controls the
flame height. These units can be equipped
with louvers for circulating or with panels for
noncirculating operation.
Fan Kit model DVFFBK are available for these
units as an option. If you are uncertain as to
what gas your unit is equipped for, please
check the rating plate located in the interior
of the appliance opening or consult your local
FMI PRODUCTS, LLC distributor.
Carbon Monoxide Poisoning:
Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness or nausea. If
you have these signs, the fireplace may not
be working properly. Get fresh air at once!
Have fireplace serviced. Some people are
more affected by carbon monoxide than oth-
ers. These include pregnant women, people
with heart or lung disease or anemia, those
under the influence of alcohol and those at
high altitudes.
Natural and Propane/LP Gas:
Natural and
propane/LP gas are odorless. An odor-making
agent is added to the gas. The odor helps you
detect a gas leak. However, the odor added to
the gas can fade. Gas may be present even
though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.
WARNING: Any change to
this fireplace or it’s controls can
be dangerous. Do not modify
this fireplace under any circum
-
stances. Any parts removed for
servicing must be replaced prior
to operating fireplace.
DANGER: Carbon monoxide
poisoning may lead to death!
Before beginning the installation of fireplace,
read these instructions through completely.
• This FMI PRODUCTS, LLC fireplace and
its components are safe when installed
according to this installation manual.
Unless you use FMI PRODUCTS, LLC
components, which have been designed
and tested for the fireplace system, you
may cause a fire hazard.
• The FMI PRODUCTS, LLC warranty will
be voided by and FMI PRODUCTS, LLC
disclaims any responsibility for the follow-
ing actions:
a. Modification of the fireplace, com-
ponents, doors, air inlet system and
damper control.
b. Use of any component part not manu-
factured or approved by FMI PROD-
UCTS, LLC in combination with a FMI
PRODUCTS, LLC fireplace system.
c) Installation and/or operation in a
manner other than instructed in this
manual.
d) Burning of anything other than the type
of gas approved for use in this gas
appliance.
This appliance, when installed, must be
electrically grounded in accordance with lo-
cal codes, or in the absence of local codes,
with the
National Electrical Code, ANSI/
NFPA 70
.
The installation must conform to local codes,
or in the absence of local codes, with the
National Fuel Gas Code ANSI Z223.1
.
This fireplace complies with the National
Safety Standards and is listed and tested by
PFS Corporation to ANSI Z21.50/CSA 2.22
standard as vented gas fireplace.
Proper installation is the most important step
in ensuring safe and continuous operation
of the fireplace. Consult the local building
codes as to the particular requirements
concerned with the installation of all factory
built fireplaces.
NOTICE: Decorative product not
for use as a heating appliance.
SAFETY
Continued