IDENTIFICATION

LOCAL CODES

Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223.1,
 also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

UNPACKING

1.

With utility knife, cut the carton all the
way around above the staples on the
bottom tray. Lift the carton off the
heater. Remove packing. 

Note:

 The

hood is located in the packing on the
right hand side of the heater front. Lift
the heater off the bottom tray.

2.

Locate two screws above top corners
of the fireplace screen. Remove and
discard these screws. Lift fireplace
screen up and pull out to remove.

3.

Remove protective packaging applied to
logs, log base assembly, and fireplace.

4.

Remove fireplace hood from carton
insert.

5.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought fireplace.

Figure 1 - Log Base Assembly

One Piece Log Set

Selector Switch
(Optional)

Piezo
Ignitor

Figure 2 - Fireplace

Top Louver
Assembly

Firebox
Hood

Bottom Louver
Assembly

Screen
Assembly

Top Outer
Casing

Firebox
Support

Blower Assembly
(Optional)

Optional Remote
Control

REMOTE CONTROL
ACCESSORIES

There are four optional remote controls that
can be purchased separately for this log
heater:

• wall switch

• wall thermostat

• hand-held ON/OFF remote

• hand-held thermostat remote

See Accessories, page 23.

Control
Knobs

 CAUTION: Do not remove the

warning and instruction labels
attached to the heater base as-
sembly. These markings contain
important warranty information.

Summary of Contents for FPVF33NR

Page 1: ...adjustment alteration ser vice ormaintenancecancause injuryorpropertydamage Re fer to this manual for correct installation and operational procedures For assistance or additional information consult a...

Page 2: ...er or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 9 This fireplace needs fresh air...

Page 3: ...fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Remove fireplace hood f...

Page 4: ...s provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION...

Page 5: ...________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors an...

Page 6: ...two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow...

Page 7: ...n the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes in cabinets Place the assembled trim onto fireplace...

Page 8: ...ng wood screws Countersink screw heads and putty over 5 Route flexible gas line through access hole in hearth base INSTALLATION Continued 6 Center cabinet mantel on hearth base see Figure 10 Make sure...

Page 9: ...e fireplace to clear thermostat valve 6 Replace bottom of firebox 7 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after th...

Page 10: ...ion If placing mantel above built in fireplace youmustmeetminimumclearancebetween mantel shelf and top of fireplace opening Figure 16 Minimum Mantel Clearances for Built In Installation INSTALLATION C...

Page 11: ...toff Valve With 1 8 NPT Tap 3 Minimum From Gas Meter 5 W C to 10 5 W C Pressure Pipe Cap Tee Nipple Joint Sediment Trap Installation Items Needed 5 16 hex socket wrench or nut driver Phillips screwdri...

Page 12: ...er 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shut...

Page 13: ...pping notches of fireplace screen over screws on front of fireplace see Figure 24 WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place screen is in place bef...

Page 14: ...battery cover onto remote con trol unit Battery Cover Terminal Wires Remote Control Unit Valve White Wire From Receiver INSTALLING 9 VOLT BATTERIES Two 9 volt batteries not included are re quired to o...

Page 15: ...witch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follo...

Page 16: ...ob anywhere between HI and LO SlidetheselectorswitchtotheRE MOTEposition seeFigure33 Note Theburners maylightifhand heldre mote ON button was on when selector switch was last turned off You can now tu...

Page 17: ...ows You to Choose the Auto Setting The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected IMPORTANT This remote control has been specially engineered to take...

Page 18: ...ealsorecommendthatyoukeeptheburner tubeandpilotassemblycleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or...

Page 19: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Page 20: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe...

Page 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Page 22: ...ct your local natural gas supplier AUTO OFF ON Thermopile WIRING DIAGRAM Note For proper operation of optional ac cessories the wires from the switch to the controlmustbeconnectedexactlyasshown REPLAC...

Page 23: ...16 BLOWER ACCESSORIES GA3700 AND GA3700T Manualvariablecontrolandautomaticther mostat control AUTO ON OFF COOLE R WARMER TEMP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT SERIES For all...

Page 24: ...105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL FPVF33NR 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22...

Page 25: ...Burner Orifice Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1...

Page 26: ...26 105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE FPVF33NR 4 11 14 18 19 20 17 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Page 27: ...Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 101872 03 Firebox Top 1 11 101346 01CK Outer Base 1 12 101838...

Page 28: ...tsrelatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...

Reviews: