17
105271
OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
Figure 35 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 36 - Incorrect Pilot Flame Pattern
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 35 shows a correct pilot flame pattern.
Figure 36 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not prop-
erly heating the thermocouple. When the
thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 36
• turn heater off (see To Turn Off Gas to
Appliance, page 16)
• see Troubleshooting, pages 19 through 21
Pilot Burner
Thermocouple
INSPECTING
BURNERS
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the
holes in the fitting at the burner entrance.
These holes may become blocked with dust
or lint. Periodically inspect these holes for
any blockage and clean if needed. Blocked
air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no flame
present. If so, turn off heater and let cool.
Either remove blockage or replace burner.
Blocked burner flame holes will create soot.
Figure 34 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)
Shows Temperature
Setting
Increases Room
Temperature in AUTO
Mode
Decreases Room
Temperature in AUTO
Mode
Turns Burners On or Off
and Allows You to
Choose the Auto Setting
The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected
IMPORTANT:
This remote control
has been specially engineered to
take an air temperature sample ev-
ery minute in the auto mode. It will
not respond immediately to the
temperature setting being turned
up or down.
IMPORTANT:
The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.
3.
To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.
Locate the blower switch by opening lower
louver on fireplace. Blower switch is lo-
cated at lower right inside louver door.
The GA3700T Series thermostat-con-
trolled blower has a variable speed con-
trol with an ON/OFF switch. The blower
will start when the thermostat senses a
sufficient increase in firebox temperature.
The GA3700 variable speed blower also
has an ON/OFF switch built into the vari-
able speed control.
Note for GA3700T Series Only:
If you
are using GA3700T blower, your fire-
place and blower will not turn on and off
at the same time. The fireplace may run
for several minutes before the blower
turns on. After the heater modulates to
the pilot position, the blower will con-
tinue to run. The blower will shut off after
the firebox temperature decreases.
Note:
It is safe to operate fireplace with
blower turned off. However, the blower helps
distribute heated air from the fireplace.
Follow installation instructions included
with the blower accessory.
OPTIONAL BLOWER
OPERATION