www.fmiproducts.com
126454-01B
20
Lava Rock and Ember Material
1. For all models, place lava rock along sides
and front of firebox bottom in areas that
are visible. It is not necessary to use all
lava rock provided.
NOTICE: Do not put lava rock
on or under burner. Placing
lava rock on burner could cause
performance problems.
2. Pull ember material apart into pieces no
larger than a dime. Place loosely and di-
rectly onto exposed section of front burner
and along space between burner and grate
prongs. These will create glowing ember ap-
pearance as flame touches ember material.
Do not block air slots by using too much
ember material in one area. It is not neces-
sary to use all ember material provided.
3. When lava rock and ember material are
in place, close and latch glass door and
replace screen door assembly.
WARNING: The glass door
must be securely in place before
operating fireplace. Do not oper
-
ate fireplace if glass is missing
or broken.
INSTALLATION
Continued
BLOWER ACCESSORY
WARNING: If there is a duplex
electrical outlet installed in the
right side of the bottom of the
fireplace base area, be sure that
the electrical power to the outlet is
turned off before proceeding with
blower installation. Failure to do
this may result in serious injury.
Model BKT
This product is equipped with a BKT blower.
The blower is located against the lower rear
wall of the firebox outer wrapper with the
exhaust port directed upward. The blower is
held in position against the back wall by the
magnets incorporated onto the blower hous-
ing (see Figure 33).
The thermal disc assembly is attached to
the outer firebox onthe upper left side of the
fireplace (see Figure 35, page 24). The ther
-
modisc must be oriented as shown Figure 35.
page 24 in order to sense temperature and
properly operate.
CAUTION: Never touch the
blower wheel while in operation.
Blower
Location
Magnets
Route BKT
Blower Through
this Area
Air Flow
Direction
Side view Firebox Bottom
DECORATIVE FACING
Any noncombustible material may be used as
facing (glass, tile, brick, etc.) as long as the
proper clearances are observed (see
Clear-
ances to Combustibles
, page 6). Screen door
assembly must not be obstructed and must
remain accessible for service. Use only heat-
resistant, noncombustible mortar or adhesive
when securing decorative facing materials.
Figure 33: Blower Mounting Location (Side View)
f i r e - p a r t s . c o m