5.3 Water inlet (only for ovens with humidifier system)
If the unit is fitted with a humidifier, the use of an anti-lime filter at the water supply inlet and a check valve is
recommended. The oven has a ¾ “ connection for water inlet.
Besides, installing a “digimeter” or digital instrument for measuring the litres of water consumed by the oven is
recommended. In this way, you will know when the filter should be replaced.
Important:
Before connecting the water supply, check that there are no residues in the pipe. The pressure of the
incoming water should range between 2 and 3 bar, with temperature not higher than 30 ºC. If pressure is higher than
these values, a pressure reducer at the inlet should be installed.