Operating instructions TSM-21
Status as of 12 / 2021
Page 13
3.2 Hopper filling level check operation
General:
The filling level in the hopper can be monitored with the filling level check.
Setting via
Function
Description
Direction of rotation
DIP 4 ON - Drive direction of rotation counterclockwise
DIP 4 OFF - Drive direction of rotation clockwise
Sensor input
(filling level sensor)
DIP 5 ON - Sensor input signal N.C.
inverted
DIP 5 OFF - Sensor input signal N.O.
not inverted
Switch-on delay
(t
on
)
Trimmer P2
Switch-on delay, filling level 0..20 s
Switch-off delay
(t
off
)
Trimmer P1
Switch-off delay, filling level 0..20 s
Switch-on delay:
The filling level in the hopper is monitored with a light barrier. If a lack of workpieces is detected by the
sensor, the switch-on delay t
on
starts. After this time elapses, the lack of workpieces output is actuated.
Switch-off delay:
Once the lack of workpieces in the hopper has been rectified, the output is reset via the adjustable
switch-off delay t
off
. The workpiece shortage output is no longer actuated.