![FLYGT 3126.290 Installation, Operation And Maintenance Manual Download Page 16](http://html1.mh-extra.com/html/flygt/3126-290/3126-290_installation-operation-and-maintenance-manual_2311487016.webp)
2
13
12
14
22
21
20
17 18
19
16
15
9
10
11
8
7
6
5
4
3
1
23
24
WS006257A
1.
Curve code or Propeller code
2.
Serial number
3.
Product number
4.
Country of origin
5.
Additional information
6.
Phase; type of current; frequency
7.
Rated voltage
8.
Thermal protection
9.
Thermal class
10. Rated shaft power
11. International standard
12. Degree of protection
13. Rated current
14. Rated speed
15. Maximum submergence
16. Direction of rotation: L=left, R=right
17. Duty class
18. Duty factor
19. Product weight
20. Locked rotor code letter
21. Power factor
22. Maximum ambient temperature
23. Read installation manual
24. Notified body, only for EN-approved Ex products
Figure 1: The data plate
Approvals
Product approvals for hazardous locations
Pump
Approval
3126.290
European Norm (EN)
• ATEX Directive
• EN 60079-0:2009, EN 60079-1:2007, EN 13463-1:2009,
EN 13463-5:2011
•
II 2 G c Ex d IIB T4 Gb
EN approval for cable entry:
• Certificate number: INERIS 02ATEX9008 U
•
II 2 G Ex d IIC Gb or I M2 Ex d I Mb
IEC
• IECEx scheme
• IEC 60079-0, IEC 60079-1
• Ex d IIB T4
FM (FM Approvals)
• Explosionproof for use in Class I, Div. 1, Group C and D
• Dust ignition proof for use in Class II, Div. 1, Group E, F and
G
• Suitable for use in Class III, Div. 1, Hazardous Locations
Product Description
14
Flygt 3126.290 Installation, Operation, and Maintenance Manual
Summary of Contents for 3126.290
Page 1: ...Installation Operation and Maintenance Manual Flygt 3126 290 ...
Page 2: ......