2-15
Configuring Your Test Set
System Configuration
The following options can be accessed from the System Configuration screen.
Light Timeout
The default light timeout is 5 seconds. To change the light timeout length:
1
Press 1 - Light.
2
Use the number keys to select the desired light duration.
3
Press F1 - Accept.
Contrast Control
To adjust the LCD contrast from darker to lighter:
1
Press 2 - Contrast.
2
Press Up arrow key - Darker or Down arrow key - Lighter.
3
Press F1 - Accept.
Power Timeout
The default value is 2 minutes. To change power timeout length:
1
Press 3 - Power Timeout.
2
Use the number keys to select the desired light duration.
3
Press F1 - Accept.
Factory Defaults
The Defaults function allows the user to restore all programmable features to
their original factory settings. Performing this function does not clear stored
telephone numbers.
The defaults are:
•
Light Timeout: 5 seconds
•
Power Timeout: 2 minutes
To reset factory default values:
1
Press 5 - Defaults.
2
At the prompt Erase Your Data?, use the number keys to select either
1 - No or 2 - Yes.
3
Press F1 - Accept.