After measurement is taken, the sector is highlighted red. This is an indication of the meas-
urement quality. Rotate shafts to the next sector and repeat the previous step for the set act-
ive points. The color of the measured sectors shows the attained measurement quality.
The proceed icon
(
1
) also indicates the attained measurement quality. In this particular
example, the number of active points set is 4 and therefore the hint (
2
) to take a further meas-
urement point.
Note: Coupling results (
3
) are displayed because three measurement points are sufficient to
determine the alignment condition.
Note
As shafts are rotated, and depending on the physical condition of the machines, the act-
ive clock sectors change color from red (quality < 40%) to amber ( quality
>40%<60%) to green (quality >60%<80%) to blue (quality >80%). Coupling results
are displayed as soon as the measurement quality attains 40% ( active clock sector
turns amber).
Once the set number of active clock measurement points is attained, measurement stops.
60
Version:2.3
On-board help