Initializing sensor
The hint "Communication error" [
1
] suggests that the sensor has not been initialized although
the laser beam may have been correctly adjusted.
Tap the detector and sensor area [
2
] to access the menu item 'Sensor list'.
Tap menu item 'Sensor list' [
1
] to view scanned sensors. The hint 'Scanning for sensor(s)' [
2
]
appears during the scanning process. As soon as the sensor is detected, it is listed down and a
green bold dot [
3
] appears next to the detected sensor.
Initialize the sensor by tapping the listed sensor. A bold blue dot [
1
] signifies that the sensor is
initialized.