CertiFiber Pro Fiber Optical Loss Test Set
Users Manual
94
Figure 30. Equipment for Power Meter Measurements
To monitor power
1
Clean and inspect the tester’s input port and the connectors
on the source and test reference cord.
2
Connect the tester to the source, as shown in Figure 31.
3
Turn on the source. On a CertiFiber Pro module, hold down
the button adjacent to the VFL port for 3 seconds.
4
On the home screen, tap
TOOLS
, then tap
Power Meter /
Light Source.
5
The default mode for the power meter is
Auto CertiFiber Pro
.
If the source is not a CertiFiber Pro tester, tap
to select the
correct mode.
Figure 32 shows the power meter and its controls.
GPU137EPS
Versiv main unit with CertiFiber
Pro module installed
One test reference cord
Fiber cleaning supplies
Video probe with USB connector
(DI-1000 shown)
AC adapter with line cords
(optional)
A
B
C
E
D
Summary of Contents for CertiFiber Pro
Page 8: ...vi CertiFiber Pro Fiber Optical Loss Test Set Users Manual...
Page 42: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 32...
Page 50: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 40...
Page 92: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 82...
Page 98: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 88...
Page 110: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 100...
Page 130: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 120...
Page 142: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 132...
Page 144: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 134...
Page 150: ...CertiFiber Pro Fiber Optical Loss Test Set Users Manual 140...