Introduction
and
Specifications
Detailed Specifications
1
1-17
Accuracy
................................................................
±
0.1
°
C
Compatibility
......................................................... Yellow Springs, Inc. (YSI) Series 400 and 700
Output
.................................................................... mini DIN 7-pin
Power-On Default
.................................................. 0
°
C (42
°
F)
Cardiac Output
Catheter Type
........................................................ Baxter Edwards, 93a-131-7f
Calibration Coefficient
.......................................... 0.542 (0
°
C injectate), 0.595 (24
°
C injectate)
Blood Temperature
............................................... 37
°
C (98.6
°
F)
±
2 %
Injectate Volume
................................................... 10 cc
Injectate Temperature
........................................... 0
°
C or 24
°
C
±
2 % value
Cardiac Output
...................................................... 2.5, 5, 10 liters per minute
±
5 %
Faulty-Injectate Curve
.......................................... Waveform for simulation available
Left-to-Right-Shunt Curve
.................................... Waveform for simulation available
Calibrated Pulse
.................................................... 1.5
°
for 1 second (37
°
→
35.5
°
)
Repeatability
..........................................................
±
1 %
Power-On Default
................................................. 2.5 liters per minute, 0
°
C injectate
Fetal / Maternal-ECG
Fetal Heart Rate (Fixed)
........................................ 60, 90, 120, 140, 150, 210, and 240 BPM
Fetal Heart Rate (IUP)
: .......................................... 140 BPM at beginning, then varies with pressure
Intrauterine-Pressure Waveforms
....................... Uniform deceleration, early deceleration, late deceleration, and uniform
acceleration
Wave Duration
....................................................... 90 seconds, bell-shaped pressure curve, from 0 to 90 mmHg and
returning to 0
IUP Period
.............................................................. 2, 3, or 5 minutes; and manual
Power-On Default
: ................................................ FHR 120 BPM, uniform deceleration wave, manual
Computer Setup
Port
......................................................................... Bidirectional (Data Communications Equipment) RS-232
Baud Rate
.............................................................. 9600
Parity
...................................................................... None
Stop Bits:
............................................................... 1
Data Bits
: ............................................................... 8
Summary of Contents for Biomedical MPS450 Operators
Page 6: ......
Page 13: ...Contents continued vii List of Figures Figure Title Page 1 1 MPS450 Patient Simulator 1 8...
Page 14: ...MPS450 Operators Manual viii...
Page 16: ......
Page 32: ...MPS450 Operators Manual 1 18...
Page 74: ...MPS450 Operators Manual 2 42...
Page 76: ...MPS450 Operators Manual 3 2...
Page 82: ...MPS450 Operators Manual 3 8...