Pressure Gauges

13

Ranges and Resolution (700GA and 700RG)

Model Number

700GA4

700GA5

700GA6

700GA27 700RG05 700RG06 700RG07 700RG08 700RG29 700RG30 700RG31

Pressure Range 
(psi)

15 PSIA

30 PSIA

100 PSIA 300 PSIA 30

100

500

1000

3000

5000

10000

Vacuum Range 
(psi)

0 PSIA

0 PSIA

0 PSIA

0 PSIA

-14

-12

-12

-14

-14

-14

-14

Burst Pressure 
(psi)

60

120

400

1200

90

400

2000

4000

10000

15000

20000

Proof Pressure 
(psi)

30

60

200

600

60

200

1000

2000

6000

10000

15000

Engineering Unit

Factor

psi

1.0000

15.000

30.000

100.00

300.00

30.000

100.000

500.00

1000.00

3000.0

5000.0

10000.0

bar

0.06894757

1.0342

2.0684

6.8948

20.684

2.0684

6.8948

34.474

68.948

206.84

344.74

689.48

mbar

68.94757

1034.2

2068.4

6894.8

20684

2068.4

6894.8

34474

68948

kPa

6.894757

103.42

206.84

689.48

2068.4

206.84

689.48

3447.4

6894.8

20684

34474

68948

MPa

0.006894757

0.1034

0.2068

0.6895

2.0684

0.2068

0.6895

3.4474

6.8948

20.684

34.474

68.948

kg/cm2

0.07030697

1.0546

2.1092

7.0307

21.092

2.1092

7.0307

35.153

70.307

210.92

351.53

703.07

mmHg @ 0 °C

51.71507

775.73

1551.5

5171.5

15515

1551.5

5171.5

25858

51715

inHg @ 0 °C

2.03603

30.540

61.081

203.60

610.81

61.081

203.60

1018.0

2036.0

6108.1

10180

20360

cmH2O @ 4 °C

70.3089

1054.6

2109.3

7030.9

21093

2109.3

7030.9

35154

70309

cmH2O @ 20 °C

70.4336

1056.5

2113.0

7043.4

21130

2113.0

7043.4

35217

70434

mmH2O @ 4 °C

703.089

10546

21093

70309

21093

70309

mmH2O @ 20 °C

704.336

10565

21130

70434

21130

70434

mH2O @ 4 °C

0.703089

10.546

21.093

70.309

210.93

21.093

70.309

351.54

703.09

2109.3

3515.4

7030.9

mH2O @ 20 °C

0.704336

10.565

21.130

70.434

211.30

21.130

70.434

352.17

704.34

2113.0

3521.7

7043.4

inH2O @ 4 °C

27.68067

415.21

830.42

2768.1

8304.2

830.42

2768.1

13840

27681

83042

inH2O @ 20 °C

27.72977

415.95

831.89

2773.0

8318.9

831.89

2773.0

13865

27730

83189

inH2O @ 60 °F

27.70759

415.61

831.23

2770.8

8312.3

831.23

2770.8

13854

27708

83123

ftH2O @ 4 °C

2.306726

34.601

69.202

230.67

692.02

69.202

230.67

1153.4

2306.7

6920.2

11534

23067

ftH2O @ 20 °C

2.310814

34.662

69.324

231.08

693.24

69.324

231.08

1155.4

2310.8

6932.4

11554

23108

ftH2O @ 60 °F

2.308966

34.634

69.269

230.90

692.69

69.269

230.90

1154.5

2309.0

6926.9

11545

23090

ft Sea Water

2.24719101

33.708

67.416

224.72

674.16

67.416

224.72

1123.6

2247.2

6741.6

11236

22472

m Sea Water

0.68494382

10.274

20.548

68.494

205.48

20.548

68.494

342.47

684.94

2054.8

3424.7

6849.4

Torr

51.71507

775.73

1551.5

5171.5

15515

1551.5

5171.5

25858

51715

* - range will not be displayed due to limitations on display resolution. In all cases, resolution is limited to 100,000 counts.

Summary of Contents for 700G0

Page 1: ...ure Gauges Users Manual November 2011 Rev 2 8 17 English 2011 2017 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies ...

Page 2: ...ation information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contamination alteration accident or abnormal...

Page 3: ...Fluke 1 Safety Information 2 Ex Hazardous Areas 4 Display and Buttons 4 Control Panel 5 Basic Operation 5 Setup the Product 6 Set Tare 7 Supervisory Mode 7 Set Custom Unit Scale 7 Maintenance 8 Clean the Product 8 Batteries 8 RS 232 Interface 10 Specifications 10 ...

Page 4: ...700G Series Users Manual ii ...

Page 5: ...teries installed and an NPT metric Adapter How to Contact Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 3 6714 3114 Singapore 65 6799 5566 China 86 400 921 0835 Anywhere in the world 1 425 446 5500 Or visit...

Page 6: ...metallic parts of the enclosure display overlay or holster with a dry cloth This action can create an electrostatic discharge Only assemble and operate high pressure systems if you know the correct safety procedures High pressure liquids and gases are hazardous and the energy from them can be released without warning Do not use the RS 232 interface in hazardous areas The RS 232 interface port must...

Page 7: ...able 1 lists the symbols that can be used on the Product or in this manual Table 1 Symbols Symbol Description W WARNING RISK OF DANGER Consult user documentation Battery status Battery P Conforms to European Union directives Certified by CSA Group to North American safety standards Conforms to relevant Australian Safety and EMC standards Conforms to relevant South Korean EMC Standards Conforms to ...

Page 8: ...plosive vapors These areas are also referred to as hazardous locations see NFPA 70 Article 500 Display and Buttons Table 2 lists the features of the Product Table 2 Product Features Item Description Item Description Pressure value D Bar graph On Off button E Control panel Pressure unit F 1 4 in NPT Connector 10K PSI 700 BAR 700G31 10K PSIG PRESSURE GAUGE 6 3 1 4 2 5 ...

Page 9: ...s the display Note For absolute versions of the gauge push to set the barometric reference pressure Within a function push to move forward through options The Product records minimum and maximum pressure values and saves them in memory Push 1X to show the maximum MAX value on the display Push 2X to show the minimum MIN value on the display Note After 2 seconds the display shows the live operation ...

Page 10: ...Sets the time before the Product automatically turns off Battery Charge Shows the battery voltage and a percent of life bar graph of the battery charge Temperature F Sets the temperature units to Celsius or Fahrenheit The Product is temperature compensated and shows the temperature on the display that is measured by an internal sensor C DAMP On Turns on off the damper The damper prevents sudden ch...

Page 11: ...actual applied pressure Supervisory Mode If needed use Supervisory mode to lock unlock functions to enable disable changes to the functions If FUnC LOCK shows on the display at least one function is locked The password for Supervisory mode is 101 The password is set at the factory and cannot be changed To open Supervisory mode 1 Push 0 PWRD shows on the display 2 Push to put in the password To mov...

Page 12: ...leaks Be sure that the battery polarity is correct to prevent battery leakage Remove the batteries if the Product is not used for an extended period of time or if stored in temperatures above 50 C If the batteries are not removed battery leakage can damage the Product Replace the batteries when the low battery indicator shows to prevent incorrect measurements Have an approved technician repair the...

Page 13: ...the battery door 2 Remove the battery door and seal 3 Replace the batteries For more information see Specifications 4 Replace the battery door and seal Note Align the battery door and seal properly with the Product to protect the Product from moisture and dust 5 Tighten the captive screw Figure 1 Battery Replacement ...

Page 14: ...on 15 C to 35 C 59 F to 95 F to rated accuracy Note For temperatures from 10 C to 15 C and 35 C to 55 C add 0 003 FS C Accuracy 700RG Ranges Positive Pressure 0 04 rdg 0 01 Full Scale Vacuum 700RG05 0 05 Full Scale Vacuum all other ranges 0 1 Full Scale Temperature Compensation 0 C to 50 C 32 F to 122 F to rated accuracy Note For temperatures from 10 C to 0 C and 50 C to 55 C add 0 005 FS C Media ...

Page 15: ...supplies buildings used for domestic purposes There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances Caution This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments Korea KCC Class A Equipment Industrial Broadcasting Comm...

Page 16: ...4 70 309 1054 6 2109 3 7030 9 21093 35154 70309 cmH2O 20 C 70 4336 28 173 70 434 1056 5 2113 0 7043 4 21130 35217 70434 mmH2O 4 C 703 089 281 24 703 09 10546 21093 70309 mmH2O 20 C 704 336 281 73 704 34 10565 21130 70434 mH2O 4 C 0 703089 0 2812 0 7031 10 546 21 093 70 309 210 93 351 54 703 09 1406 2 2109 3 3515 4 7030 9 mH2O 20 C 0 704336 0 2817 0 7043 10 565 21 130 70 434 211 30 352 17 704 34 14...

Page 17: ...0 20360 cmH2O 4 C 70 3089 1054 6 2109 3 7030 9 21093 2109 3 7030 9 35154 70309 cmH2O 20 C 70 4336 1056 5 2113 0 7043 4 21130 2113 0 7043 4 35217 70434 mmH2O 4 C 703 089 10546 21093 70309 21093 70309 mmH2O 20 C 704 336 10565 21130 70434 21130 70434 mH2O 4 C 0 703089 10 546 21 093 70 309 210 93 21 093 70 309 351 54 703 09 2109 3 3515 4 7030 9 mH2O 20 C 0 704336 10 565 21 130 70 434 211 30 21 130 70 ...

Page 18: ...700G Series Users Manual 14 ...

Reviews: