FW-F090-A-PL-M_v0403_07_EN.docx
Page 24
APPENDIX A: TECHNICAL SPECIFICATION
Display
Type
High intensity reflective numeric and alphanumeric LCD, UV-resistant.
Digits
5 ½ 26mm (1") and eleven 8mm (0.31"). Various symbols and measuring units.
Piegraph
10 segment range indication in relation to its measuring range 0-100%
Refresh rate
1 times/sec.
Type ZB (option)
Bi-color configurable LED-backlight - green or amber. Intensity adjustable from the keyboard.
Enclosures
General
Control Keys
Painting
Die-cast aluminum or GRP (Glassfibre Reinforced Polyamide) enclosure with Polycarbonate
window, silicone and EPDM gaskets. UV stabilized and flame retardant material.
Three industrial micro-switch keys. UV-resistant silicone keypad.
Aluminum enclosure only: UV-resistant 2-component industrial painting.
Panel-mount enclosures
Classification
Panel cut-out
Type HC
Type HB
Dimensions: 130 x 120 x 60mm (5.10" x 4.72" x 2.38")
–
LxHxD.
IP65 / NEMA4
115 x 98mm (4.53" x 3.86") LxH.
GRP panel-mount enclosure
Aluminum panel-mount enclosure
Field/wall-mount enclosures
Classification
Aluminum enclosures
Type HA
Type HM
Type HN
Type HO
Type HP
Type HT
Type HU
Type HV
Type HZ
GRP enclosures
Type HD
Type HE
Type HF
Type HG
Type HJ
Type HH
Type HK
Dimensions: 130 x 120 x 75mm (5.10” x 4.72” x 2.95”) –
LxHxD.
IP67 / NEMA4X
Drilling: 2x PG9
–
1x M20.
Drilling: 2x M16
–
1x M20.
Drilling: 1x M20.
Drilling: 2x M20.
Drilling: 6x M12.
Drilling: 1x ½”NPT.
Drilling: 3x ½”NPT.
Drilling: 4x M20
No drilling.
No drilling.
Drilling: 2x 16mm (0.63”) –
1x 20mm (0.78”).
Drilling: 1x 22mm (0.87”).
Drilling: 2x 20mm (0.78”).
Drilling: 3x 22mm (0.87”).
Drilling: 6x 12mm (0.47”).
Flat bottom - no drilling.
Operating temperature
Operational
-40°C to +80°C (-40°F to +178°F).
Intrinsically Safe
-40°C to +70°C (-40°F to +158°F).
Power requirements
Type PL
Input loop powered from 4-20mA signal input. Voltage drop max. 2.6V DC
Type ZB (backlight)
20-30V DC. Power consumption max. 1 Watt.
Note I.S. application for intrinsically safe applications, consult the safety values in the certificate.
Terminal connections
Type:
Removable plug-in terminal strip. Wire max. 1.5mm2
Data protection
Type
EEPROM backup of all setting. Data retention at least 10 years.
Pass code
Configuration settings can be pass code protected.
GENERAL