FW-F090-A-PL-M_v0403_07_EN.docx
Page 21
5.3.
CONFIGURATION EXAMPLE INTRINSICALLY SAFE APPLICATION:
Configuration example
Fig. 10: Configuration example Intrinsically Safe.
Configuration example IIA - IIB and IIC application - F090-A-PL-XI-ZB
TERMINAL CONNECTORS
F0-series
1
2
Common ground
Signal
C
irc
ui
t d
ep
en
ds
o
n
ty
pe
o
f s
ig
na
l
9
1
0
Common ground
Supply backlight
HAZARDOUS AREA
SAFE AREA
+
-
Power supply
For example
MTL5025
= max. 30 V
= max. 200 mA
= max. 0,75 W
Uo
Io
Po
Note: above values are safety values.
Consult the technical specification for operational values.
+
-
Power supply
For example
MTL5025
= max. 30 V
= max. 93 mA
= max. 0,92 W
Uo
Io
Po
I.S. sensor - input type A-PL: 4-20mA input loop powered.
Backlight option: type ZB
Sensor supply is not available: unit is input loop powered (type PL).
Please note: type PL may be used in combination with the battery (type PC). PL will power the unit; the battery will be disabled automatically till power is disconnected.