Historical day totals
Besides directly reviewing the Current Day Total and Previous Day Total, a list of the last 15
Previous Day Totals is saved.
LOG
0
00
1
10
30
20
80
90
70
GAL
TOTAL
Fig. 7:
Example of historical day total from 8 days ago
The list can be reviewed in LOG-mode in the following way:
1. From OPERATOR-mode, press the CLEAR-key for 3 seconds.
2. Press the SELECT- and CLEAR-keys to scroll up and down through the list of Previous Day
Totals. The number that is displayed on the left of the bottom line indicates the age of the shown
Previous Day Total, in days. Note that the entry with age ‘00’ represents the (running) Current
Day Total.
3. To return to the OPERATOR-mode again, press the PROG-key for 3 seconds or wait for 3
minutes.
4.4.4
LINE TEMPERATURE
Several times a second, the input value of the temperature sensor is measured. Temperature is
calculated based on the configuration settings for
SETUP
5: TEMPERATURE - WITH TYPE TA (4-20MA) [»27]
SETUP
5: TEMPERATURE - WITH TYPE TP (PT100) [»27]
and shown on the display with the configured number
of decimals and (display) unit.
4.5
OPERATOR ALARMS
4.5.1
LOW BATTERY
When a battery is used to supply the unit (Type PB) and the battery voltage becomes too low during
operation, the battery indicator comes on to warn that the unit is becoming less reliable. It is advised
to install a new battery (as soon as possible) as described in
Section 7.3: Replace battery [»54]
.
Fig. 8:
Low battery alarm
4.5.2
RANGE ERROR
When the input value of the pressure sensor is out of the calibrated measurement range
(e.g. due to a wire break or a faulty sensor), a range error is raised: The alarm flag starts
flashing and the text RANGE ERROR is shown on the temperature screen.
ALARM