FW-E112-P-MAN-EN_v0101_08
Page 40
Sensor excitation
Type AH/PB/PX
Note:
Terminal S3: 3V DC for pulse signals and 1.2V DC for coil pick-up.
This is not a real sensor supply. Only suitable for pulse sensors with a very low power
consumption like coils (sine wave) and reed-switches.
Type PD
Terminal P4: 8.2 – 12 and 24V DC
8.2V DC -I
out
max. 25mA (Supply voltage should be at least 12V)
12V DC -I
out
max. 30mA (Supply voltage should be at least 15V)
24V DC -I
out
max. 75mA (this voltage varies depending on the input supply voltage and is
approximately 1V lower)
Terminal connections
Type:
Removable plug-in terminal strip
Wire max. 1.5mm
2
and 2.5mm
2
Data protection
Type
EEPROM backup of all setting. Backup of running totals every minute.
Data retention at least 10 years.
Pass code
Configuration settings can be pass code protected.
Hazardous area
Explosion proof
ATEX approvals:
power consumption
≤
4.2 W
power consumption
≤
9.2 W
II 2 G Ex d IIC T6 Gb
II 2 G Ex d IIC T5 Gb
II 2 D Ex tb IIIC T85°C Db
II 2 D Ex tb IIIC T100°C Db
IECEx approval:
power consumption
≤
4.2 W
power consumption
≤
9.2 W
Ex d IIC T6 Gb
Ex d IIC T5 Gb
Ex tb IIIC T85 °C Db
Ex tb IIIC T100 °C Db
CSA (c us) approval:
Pending according XP CI I II III Div 1 GP A, B, C, D, E, F, G.
FM (c us) approval:
Pending according XP CI I II III Div 1 GP A, B, C, D, E, F, G.
Ambient Ta: -40°C to +70°C (-40°F to +158°F)
Enclosure: IP66/67, NEMA 4X
Directives & Standards
EMC
EN 61326-1 and FCC 47 CFR part 15
Low voltage
EN/IEC 61010-1
ATEX / IECEx
EN/IEC 60079-0, EN/IEC 60079-1, EN/IEC 60079-7, EN/IEC 60079 -31
FM
FM Class No. 3600, FM Class No. 3615
CSA
CSA 22.2 No. 30, CSA 22.2 No.94-M91
IP & NEMA
EN 60529 & NEMA 250
Flowmeter
Type P
Coil/sine wave (minimum 20mVp-p or 80mVp-p - sensitivity selectable), NPN/PNP, open
collector, reed-switch, Namur, active pulse signals 8.2/24V DC.
Frequency Minimum 0 Hz - maximum 7 kHz for total and flowrate.
Maximum frequency depends on signal type and internal low-pass filter.
E.g. Reed switch with low-pass filter: max. frequency 120 Hz.
K-Factor 0.000010 - 9,999,999 with variable decimal position.
Low-pass filter Available for all pulse signals.
Linearization 15 positions with interpolation function; Meter-Factor 0.000001 - 9.999999 versus Frequency
0.001 Hz - 9,999 Hz.
Option ZF coil sensitivity 10mVpp
Option ZG coil sensitivity 5mVpp.
INPUTS