Inst.434 Viron XT Pool & Spa Pump V08_17
3
FEATURES
-
Continuous duty rated motor
-
Precision reinforced moulded high head impeller, giving extra performance
-
Single piece moulded body for added strength and longer life
-
Rapid priming diffuser quickly corrects loss of water flow
-
Quick and easy disassembly for servicing
-
Large capacity basket with easily removed ramp on lid
-
Ability to adjust factory pre-set speeds for optimum water flow and maximum energy savings for your pool and its
equipment.
-
Double Insulated water circuit for maximum electrical protection
DIMENSIONS
INSTALLATION
This appliance must be installed by a trained pool professional service technician. When installing the appliance, ensure all
parts are installed in the correct zone in accordance with the wiring rules. In particular refer to AS/NZS 3000 (Australia) and
EN 60364 (EU).
A.
Plan
position of pump so that it will be:
1.
Free of water flooding, such as in a sump, garden hollow, ditch or at bottom of bank with run off.
2.
On a stable base so that:
a)
The pump is not left suspended by its fittings, causing a leak or failure with loss of water.
b)
Movement through vibration is restricted
c)
No strain is put on attaching pipe or other expensive equipment
3.
Accessible
for maintenance and easily removed for service.
4.
Breathing space. Pump should not be crowded which will prevent cooling airflow from fan. Overheating
due
to lack of cooling voids warranty.
5.
Within reach
of power point without extension/plugs liable to corrosion, shorting, etc.
6.
At a minimum
height of suction lift of water from pool surface to pump inlet.
B.
For best pump performance keep suction pipe length as short as possible with minimum number of bends and use
50mm high pressure PVC suction and return pipe. All equipment such as filters, heaters, chlorinators must have a
minimum of 50mm connections.
C.
Secure the barrel unions supplied into the attaching pipe work, using approved priming fluid and solvent cement as
normal practice, coating both surfaces. NOTE: Always wear protective gloves when handling and using glue and
priming fluid. Ensure no excess adhesive runs into the union proper affecting the sealing or removal abilities.
Allow 24 hours to dry before starting pump. Do not use “green” glue on barrel unions. This can cause damage to
the ABS material used to manufacture the unions.
D.
Install isolation valves before the pump section and after equipment, if the pump is below the water level of the
pool.
E.
For pump installations 500mm above water level, it generally requires a foot valve at the pool or check valve in the
suction line. Suction lines must be installed below water level until just in front of pump location and vertical riser
used to reach pump inlet. AstralPool pumps are rated to a maximum head of 25 meters however refer to your
pumps data plate for actual achievable pressure