Inst.434 Viron XT Pool & Spa Pump V08_17 

11.  When cycling through the Menu button TMR will no longer appear 
12.  You will no longer be able to automatically have the speed of the pump changed during different times of 

the day. 

13.  However, if you wish for a period where the pump operates at a high speed, for example to circulate the 

water vigorously for a part of the daily filtration, you can use the PRIMING setting to do so. 

Using the PRIMING program to circulate the water at a higher flow rate for part of the daily filtration cycle. 

1.  Have PUMP in MANUAL OFF  
2.  Press MENU BUTTON TWICE until PRIM appears on the screen 
3.  Press ENTER To show current Speed, use UP DOWN buttons to Adjust speed. Adjusts in 25 RPM 

increments. Once Speed is selected Press ENTER.  (Similarly to HIGH Speed, PRIME speed can be set 
to overdrive mode by using the Up button to increase the speed above normal high speed) We 
recommend high speeds for Priming 

4.  PRIMING TIME will now appear on the screen. Prime period is defaulted to 5 minutes and high speed.   

Use the up and down arrows to change the Priming period From 2 minutes up to 120 minutes. Press 
ENTER to accept, Screen will Flash  

5. 

Press “Auto” to exit the programming. 

Using Pump with AstralPool compliant external control 

AstralPool manufactures Salt Chlorinators, EQ chemical dosing units or the Viron Connect Touch Screen Control 
system which can control both the operating times of the all Viron XT pumps PLUS the speed the pump operates 
at during each timer period. 
For the P320 & P520 you must enable the communication port and disable the Pump in built timers. 

1.  Toggle Menu until CONF (configure) appears. Hold enter for 3 seconds. 
2.  Toggle 

Menu until “TMR” appears. 

3.  Press UP or 

Down buttons to turn “TMR OFF”.  Remember, you are now using the external control to set 

the pump operating hours, so the pump timer must be turned off. 

4. 

Press “enter” to accept 

5.  Toggle menu until SYS (system) appears.  Press the 

up or down 

 button and tur

n to “ON”.  The Viron 

P320 or P520 XT will accept the start, end and pump speed instructions from the AstralPool compliant 
control chlorinator EQ & Rolachem dosing controller or Viron Connect Touch Screen Control. 

6.  Press 

 

“auto” to return to main menu. 

7.  The time will still be visible on the LCD display however, the timer function in the menu setting will no 

longer appear.  Toggle the menu button will now only display PRIM (priming program), CLK (clock setting) 
and CONF (Configuration menu). 

8.  Refer to your AstralPool compliant Chlorinator, EQ,,RolaChem Dosing Control or Viron Connect Touch 

Screen Control manual for details of programming the pump speed and operating hours. 

Fault Codes 
The P320 & P520 Pump only 

Fault Code (displayed on screen) 

Meaning 

HI T 

Over Temperature 

HI A 

Over Current 

Lo V* 

Under Input Voltage 

BSUC 

Motor is Stuck 

*Please note: It is normal for the “Lo V” fault code to display briefly on start up.   

Data cable connector:

 

 

If a compatible AstralPool VX Salt Chlorinator, Viron Salt Chlorinator or Viron Connect Touch Screen, is connected 
with the AstralPool communication cable, the speed of the pump and operating hours can be controlled by these 
devices. 

The Viron P320 & P520 XT must have its inbuilt timer deactivated if the pump operating times and speeds are to be 
operated by the compatible AstralPool Salt Chlorinator EQ, RolaChem Dosing Controller or Viron Connect remote touch 
screen. 
Remove 2 Philips head screens from rear of pump and the data port cover is removed by hand.  Plug RJ12 6 wire flat cable 
purchased from AstralPool into rear of pump and reassemble. To achieve a proper seal, press the flat cable under the guide 
tabs (detailed view A). Slide data port cover back on by aligning the tabs with the slots and the flat cable with the recess 
(detailed view B).   

 

Summary of Contents for Astralpool Viron P320 XT

Page 1: ...ING INSTRUCTIONS sales astralpool com au www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Viron P320 XT...

Page 2: ...EALER OPERATING PUMP IN OVERDRIVE MODE WILL CREATE VERY HIGH WATER PRESSURE ENSURE ALL CONNECTIONS ARE WATER TIGHT STAND CLEAR OF ANY FILTER LIDS AND OTHER EQUIPMENT IN THE SYSTEM WHEN OPERATING IN OV...

Page 3: ...ded which will prevent cooling airflow from fan Overheating due to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum...

Page 4: ...ulty seal cracked lint pot lid etc 7 The Viron XT has 3 factory pre set speed settings Low Medium and High High should be used when backwashing manually vacuuming the pool or operating spa jets or som...

Page 5: ...to ensure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples o...

Page 6: ...ed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an ex...

Page 7: ...flash while editing 3 The new speed will automatically save after 2 seconds Flashing will stop to signal save Setting filtration timer periods 1 Press Menu to go to PRIM setting 2 Prime period is defa...

Page 8: ...g the external control to set the pump operating hours so the pump timer must be turned off 4 Press enter to accept 5 Toggle menu until SYS system appears Press the up or down button and turn to ON Th...

Page 9: ...um or high speed can be selected for each timer period Data cable connecting pump to chlorinator via Comms interface module XTPump to be set up with timer periods deactivated Pump speed can be changed...

Page 10: ...er To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of...

Page 11: ...nt to activate the pressure switch and control circuit within the heater If using a compatible AstralPool Gas Heater you can automatically increase the speed of your Viron XT pump to ensure the water...

Page 12: ...ces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Timing Maintenance Check Service action if required Weekly or sooner Check and empty hair and li...

Page 13: ...E E TIM E R 3 STOP TIM E E TIM E R 4 STA RT TIM E E TIM E R 4 STOP TIM E M PRIM M OFF ON CONF E ON OFF E E CURRENT PRIM E SPEED NEW PRIM E SPEED NEW PRIM E DURATION CURRENT PRIM E DURATION E CURRENT I...

Page 14: ...e alleged defect and c appropriate documentation such as historical and maintenance records 3 The customer must make the Product available to AstralPool or its Authorised AstralPool Service Agent for...

Page 15: ...performance or life of the equipment will void the warranty Insect infestation or penetration by sand dust or other foreign bodies will void warranty Where in field labor warranty is provided a 20km...

Page 16: ...t 434 Viron XT Pool Spa Pump V08_17 16 INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIO...

Reviews: