background image

Inst.434 Viron XT Pool & Spa Pump V08_17 

OPERATION OF CONTROL PANEL – VIRON P320 & P520 XT (CONT…) 

Using the in built timer to operate pump with an AstralPool Chlorinator or EQ dosing unit 

Factory Default Setting 

1.  The inbuilt timers are activated and will control the time the pump operates 
2.  Connectivity to AstralPool compliant Salt Chlorinators, EQ Chemical dosing controllers or Viron Connect 

remote Controls i

s turned “off” 

3.  Use the 

 

“auto” button to turn the pump on or off.  When in on position, the pump will remain off until 

the next timer period unless pressed again to manually on.  If pump is turned to manually on, it will 
continue to operate indefinitely.   

If in the “Off” position (visible on the LCD), the pump will remain 

indefinitely off.   For timer operation, ensure the “auto” button is pressed so that the LCD screen displays 
“auto”. 

Setting the current Time 

1.  If connected to a compliant AstralPool Salt Chlorinator or EQ dosing controller connect data cable 

between rear of pump and the chlorinator in EQ dosing unit. 

2.  Connect and turn power on to the pump and Chlorinator (or dosing unit) 
3. 

Have pump set in “MANUAL OFF”  

4.  Press 

“MENU BUTTON” ONCE “CLK” appears and press “enter” to set time.  Use 

up and down 

 

arrows to set the hour, press “enter” again to set minutes and then press “enter” again to set AM or PM. 

5.  Press 

 Auto 

“enter” to accept 

6.  The LCD screen will quickly flash 3 times to indicate the new setting has been accepted. 

Setting pump to operate independently of external AstralPool Compliant Chlorinator or Control System 

1.  Toggle 

Menu until “CONF” is displayed on the LCD screen 

2. 

Press and HOLD “enter” for 3 seconds. “TMRS” will appear. 

3. 

Press “enter” 

4.  Press U

P or Down buttons to turn “TMRS ON” 

5. 

Press “enter” to accept 

6.  Press 

 

“auto” to return to main menu. 

Changing Low, Med and High Speed Settings 

1.  Select the Speed Button to be adjusted, Low, Medium or High. Respective LED will light up. 
2.  Alter the speed in increments of 25 RPM using the up and down arrows until the desired speed is 

displayed on the screen. Respective “Speed 1”, Speed 2” or “Speed 3”, will flash while editing. 

3.  The new speed will automatically save after 2 seconds. Flashing will stop to signal save. 

Setting filtration timer periods 

1.  Press Menu to go to PRIM setting. 
2.  Prime period is defaulted to 5 minutes and high speed.   We recommend if your pump is installed at or 

below water level, you change the PRIM to 2 minutes.  Press “enter” and then Up or Down arrows to 
change the prime speed. 

Press “enter” to accept. Priming period will now be displayed. 

3. 

Use the Up or Down arrow to change the Priming period. Press “enter” to accept. 

4. 

Press Menu to go to TMR “timer settings” and press “enter” to change. 

5.  Timer 1 is factory set to start at 8 am.   Use up or down arrows to change.   Press High, Medium, or Low to 

select the speed of the pump during Timer 1.   On the LCD Screen High is represented by speed “1”, 
medium by speed “2”, and Low by speed “3”. 

6.  Press Enter to move to the stop or end time of Timer 1.  Use the up and down arrows to change the end of 

Timer 1. 

7.  Timer 2 will now appear on the LCD Screen.  Repeat instructions 4. to 6. Above. 
8.  Timer 3 will now appear but is factory pre-set to OFF.   Moving any timer to midnight will turn that Timer 

period off.  Use the up and down arrows to activate the time and repeat process 4 and 5 above. 

9.  Timer 4 is also factory pre-set 

to “off” but can be activated by using the up and down arrows. 

10.  Remember to select the speed you wish to operate during each timer period by pressing the High, Medium 

or Low buttons while still in the Timer Start program. 

Using the in built pump timers with a non compliant chlorinator or dosing unit. 

1.  We do not recommend the use of the pump timers when a non compliant chlorinator or chemical doser is 

supplied water flow by the Viron P320 or P520 XT pump.    

2.  In this case, the pump operating hours should be controlled by the chlorinator time clock and the pump 

plugged into the chlorinator.  This is a safety measure provided for by most chlorinator manufacturers. 

3.  However, it is important to deactivate the inbuilt pump timers. 
4. 

Have Pump in “MANUAL OFF” 

5.  Toggle 

Menu until “CONF” is displayed on the LCD screen 

6. 

Press and HOLD “enter” for 3 seconds 

7.  Toggle Menu un

til “TMR” appears. 

8. 

Press UP or Down buttons to turn “TMR OFF” 

9. 

Press “ENTER” to accept 

10.  Press 

 

“AUTO” to return to main menu. 

Summary of Contents for Astralpool Viron P320 XT

Page 1: ...ING INSTRUCTIONS sales astralpool com au www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Viron P320 XT...

Page 2: ...EALER OPERATING PUMP IN OVERDRIVE MODE WILL CREATE VERY HIGH WATER PRESSURE ENSURE ALL CONNECTIONS ARE WATER TIGHT STAND CLEAR OF ANY FILTER LIDS AND OTHER EQUIPMENT IN THE SYSTEM WHEN OPERATING IN OV...

Page 3: ...ded which will prevent cooling airflow from fan Overheating due to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum...

Page 4: ...ulty seal cracked lint pot lid etc 7 The Viron XT has 3 factory pre set speed settings Low Medium and High High should be used when backwashing manually vacuuming the pool or operating spa jets or som...

Page 5: ...to ensure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples o...

Page 6: ...ed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an ex...

Page 7: ...flash while editing 3 The new speed will automatically save after 2 seconds Flashing will stop to signal save Setting filtration timer periods 1 Press Menu to go to PRIM setting 2 Prime period is defa...

Page 8: ...g the external control to set the pump operating hours so the pump timer must be turned off 4 Press enter to accept 5 Toggle menu until SYS system appears Press the up or down button and turn to ON Th...

Page 9: ...um or high speed can be selected for each timer period Data cable connecting pump to chlorinator via Comms interface module XTPump to be set up with timer periods deactivated Pump speed can be changed...

Page 10: ...er To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of...

Page 11: ...nt to activate the pressure switch and control circuit within the heater If using a compatible AstralPool Gas Heater you can automatically increase the speed of your Viron XT pump to ensure the water...

Page 12: ...ces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Timing Maintenance Check Service action if required Weekly or sooner Check and empty hair and li...

Page 13: ...E E TIM E R 3 STOP TIM E E TIM E R 4 STA RT TIM E E TIM E R 4 STOP TIM E M PRIM M OFF ON CONF E ON OFF E E CURRENT PRIM E SPEED NEW PRIM E SPEED NEW PRIM E DURATION CURRENT PRIM E DURATION E CURRENT I...

Page 14: ...e alleged defect and c appropriate documentation such as historical and maintenance records 3 The customer must make the Product available to AstralPool or its Authorised AstralPool Service Agent for...

Page 15: ...performance or life of the equipment will void the warranty Insect infestation or penetration by sand dust or other foreign bodies will void warranty Where in field labor warranty is provided a 20km...

Page 16: ...t 434 Viron XT Pool Spa Pump V08_17 16 INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIO...

Reviews: