6.APPENDIX
22
6.2 Cable specification
(1) Single phase unit
Nameplate
maximum
current
Phase line
Earth line
MCB
Creepage protector
Signal line
No more
than 10A
2
x
1.5mm
2
1.5mm
2
20A
30mA less than 0.1 sec
n
x
0.5mm2
10~16A
2
x
2.5mm
2
2.5mm
2
32A
30mA less than 0.1 sec
16
~25A
2
x
4mm
2
4mm
2
40A
30mA less than 0.1 sec
25
~32A
2
x
6mm
2
6mm
2
40A
30mA less than 0.1 sec
32
~40A
2
x
10mm
2
10mm
2
63A
30mA less than 0.1 sec
40
~63A
2
x
16mm
2
16mm
2
80A
30mA less than 0.1 sec
63~75A
2
x
25mm
2
25mm
2
100A
30mA less than 0.1 sec
75~101A
2
x
25mm
2
25mm
2
125A
30mA less than 0.1 sec
101~123A
2
x
35mm
2
35mm
2
160A
30mA less than 0.1 sec
123~148A
2
x
50mm
2
50mm
2
225A
30mA less than 0.1 sec
148~186A
2
x
70mm
2
70mm
2
250A
30mA less than 0.1 sec
186~224A
2
x
95mm
2
95mm
2
280A
30mA less than 0.1 sec
(2) Three phase unit
Nameplate
maximum
current
Phase line
Earth line
MCB
Creepage protector
Signal line
No more
than 10A
3
x
1.5mm
2
1.5mm
2
20A
30mA less than 0.1 sec
n
x
0.5mm2
10~16A
3
x
2.5mm
2
2.5mm
2
32A
30mA less than 0.1 sec
16
~25A
3
x
4mm
2
4mm
2
40A
30mA less than 0.1 sec
25
~32A
3
x
6mm
2
6mm
2
40A
30mA less than 0.1 sec
32
~40A
3
x
10mm
2
10mm
2
63A
30mA less than 0.1 sec
40
~63A
3
x
16mm
2
16mm
2
80A
30mA less than 0.1 sec
63~75A
3
x
25mm
2
25mm
2
100A
30mA less than 0.1 sec
75~101A
3
x
25mm
2
25mm
2
125A
30mA less than 0.1 sec
101~123A
3
x
35mm
2
35mm
2
160A
30mA less than 0.1 sec
123~148A
3
x
50mm
2
50mm
2
225A
30mA less than 0.1 sec
148~186A
3
x
70mm
2
70mm
2
250A
30mA less than 0.1 sec
186~224A
3
x
95mm
2
95mm
2
280A
30mA less than 0.1 sec
W
hen the unit will be installed at outdoor, please use the cable which can against UV.
Summary of Contents for Astral Pool IHPt127