background image

• See troubleshooting on Page 27 if needed.

Congrats, You’re Finished!

Welcome to the Peachy Clean Life!

Happy Bum. Happy Life.

YOU DID IT!

We knew you could!

Share your success story with friends and family!

#HappyBum

#PeachyCleanLife

#Fluidmaster

Summary of Contents for soft spa 9500

Page 1: ...ster you will need to READ ALL instructions completely prior to installation and use READ ALL warnings care and maintenance information Ensure you have all the components and tools needed for installa...

Page 2: ...n Test P 18 Remote Control Functions P 20 Remote Control Technical Specifications P 24 Remote Control Mount Install and Maintenance P 25 Electrical Protection Test P 26 Troubleshooting P 27 Warranty P...

Page 3: ...dropped into water Return the product to a service center for examination and repair 7 Keep the power cord away from the heating surface 8 Do not clog holes in the nozzle or dryer or place the product...

Page 4: ...cause a fire electric shock or bodily injury DO NOT supply electrical power to the unit until it has been installed on the toilet and the water supply lines have been properly connected This can cause...

Page 5: ...m the unit Sitting on the heated seat or using the dryer for an extended period of time can potentially cause first degree burns Exercise special precautions for children those who cannot or have diff...

Page 6: ...circuit could cause the branch circuit fuse to blow or the circuit breaker to trip Continuous usage under these conditions may result in fire or property damage WARNING GROUNDING INSTRUCTIONS This app...

Page 7: ...DING PIN ADAPTER ADAPTER METAL SCREW TAB for Grounding Screw GROUNDED OUTLET GROUNDED OUTLET BOX A B C PREFERRED CONNECTION TEMPORARY CONNECTION CAUTION The use of an extension cord is not recommended...

Page 8: ...ut and washer optional D 1x Seat template E 1x T valve 1x Rubber washer F 1x Mounting Plate G 1x 20 Supply line connector H 1x 16 Supply line connector I 3x Threaded supply line adaptors B E Additiona...

Page 9: ...of the ceramic Ceramic is invisible C Area C aligns the fixing plate Area A is folded No Good Area C aligns the fixing plate OK The edge of ceramic is visible No Good A Rear edge of area A is not all...

Page 10: ...y flushing the toilet 2 Place a towel on the floor under the supply line connector 3 Remove the old supply line connector 4 Remove your existing toilet seat 5 Clean the surface of the bowl around the...

Page 11: ...hrough the bottom of the hole on the underside of your toilet If you are still having issues see page 27 C Place mounting plate F on top of grommets D Align the center of each sliding rail C flat side...

Page 12: ...ward until the front edge of the template lines up with the front edge of the toilet rim C Once aligned secure mounting template in place by tightening screws until the mounting plate no longer slides...

Page 13: ...ired placement If adjustment is needed remove the bidet by pressing the quick release button on the right side of the base and sliding the bidet off the toilet If you don t hear an audible click make...

Page 14: ...cant water leakage and water damage C Secure the 16 supply line connector H by threading the metal nut onto the external valve B Locate the external valve on the left side of the bidet Rotate it out o...

Page 15: ...or the use of tools could cause damage and lead to failure of the nut and or fill valve Such damage may not be visible to the eye Failure of the nut and or fill valve can lead to significant water lea...

Page 16: ...20 connector G onto the bottom opening of the T valve using only your hands Overtightening and or the use of tools could cause damage and lead to failure of the nut Such damage may not be visible to t...

Page 17: ...and water damage B Slowly turn the water supply on and check for leaks at the valve C Once all supply lines are securely installed remove the tape from the wand cover and plug in your bidet Check tha...

Page 18: ...activated press the REAR and FRONT cleaning buttons on the remote to ensure proper nozzle function See remote guide on page 20 CAUTION Read carefully the following information on the seat temperature...

Page 19: ...ng on Page 27 if needed Congrats You re Finished Welcome to the Peachy Clean Life Happy Bum Happy Life YOU DID IT We knew you could Share your success story with friends and family HappyBum PeachyClea...

Page 20: ...SEAT TEMPERATURE POSITION DEODORIZER GENTLE DRY FRONT OSCILLATE REAR OSCILLATE AUTOMATIC WORKING MODE STOP WATER TEMPERATURE INDICATION LIGHTS NIGHT LIGHT WATER PRESSURE Your Soft Spa 9500 will keep t...

Page 21: ...cleaning cycle ends Recommended for children elderly patients those who are physically limited cannot adjust the temperature or have sensitive skin 15 seconds of cleaning at fixed position 60 seconds...

Page 22: ...ou reach your desired water temperature WATER TEMPERATURES Off Inlet water temperature First level 30 C 2 C 86 F Second level 32 C 2 C 90 F Third level 34 C 2 C 93 F Fourth level 36 C 2 C 97 F Fifth l...

Page 23: ...Unit will resume normal function upon next use Bidet Base Buttons QUICK RELEASE Depress fully to remove bidet Always move from the base of the bidet never the seat or lid to avoid damage AUTOMATIC WOR...

Page 24: ...ade IPX4 Air Temperature Adjustment 3 Level Setting Normal Temperature Level Water Temperature Inlet water temperature 38 C 100 F Seat Heating Seat Temperature Adjustment 5 Level Setting Normal Temper...

Page 25: ...ad drill bit 4 Install AAA batteries into the remote control and insert into mount Cleaning and Maintenance Wipe with a soft cloth and water only to maintain appearance and avoid damaging the surface...

Page 26: ...ssed 2 While the unit and indicator light are both off press the TEST button 3 Press the RESET button Once released power to the unit and the indicator light will turn on and the unit will resume norm...

Page 27: ...water temperature level indicator light and alarm functions If any of these issue occur please immediately cut off the power supply and contact Fluidmaster Technical Services 800 631 2011 for further...

Page 28: ...Tech Services The AUTO STOP button flashes red consecutively 6 times in a row Seat temperature sensor fault Turn off the heated seat feature and contact Fluidmaster Tech Services The leakage protectio...

Page 29: ...at temperature will automatically rise as you sit on the product This is normal while in energy saving mode Dry Function The temperature is too low Is the Dry temperature set to a lower state Increase...

Page 30: ...30 NOTES...

Page 31: ...31 NOTES...

Page 32: ...30800 Rancho Viejo Road San Juan Capistrano CA 92675 www Fluidmaster com 800 631 2011 Contact Fluidmaster for troubleshooting help or visit www Fluidmaster com M F 5 30 am 5 00 pm PST 52 1038 Grev 1...

Reviews: